{"title":"用气体压力传感器和连续性方程检测家用LPG配气管道泄漏位置","authors":"Anang Suryana, Mukhlis Ali, Samsul Pahmi, Muhammad Mahmud, Duddy Suherman, A. Dera, Ilham Fazrul Iman, Teja Nuralam","doi":"10.1109/ICCED51276.2020.9415775","DOIUrl":null,"url":null,"abstract":"Factors causing pollution both water and air and fires can be caused by the pollution of liquefied petroleum gas (LPG) that comes from gas network leaks from National gas Company (PGN) to households. For National gas Company (PGN) due to LPG gas pipeline leaks can cause quantitative losses. To prevent losses caused by LPG network leaks that are distributed to households, a gas pipeline leak detection system can be applied using the concept of fluid mechanics. Where the position of the gas pipe leakage can be known by the difference in gas pressure at the two ends of the pipe. The difference in pressure on the small gas pipe after the calculation by including the friction factor then the pipe has a leak, but if the difference is greater then the pipe is in normal condition. To detect leaks quickly, the pressure monitoring data will be monitored in a database that is displayed in front end point of the location of leakage of household gas pipes to officers who monitor the performance of the household gas pipeline. The results of this study indicate that the distance or position of the gas leak in the gas pipeline network can be measured by the difference between the two pressures at both ends of the gas pipe that is leaking. The error resulting from the reading of the pressure sensor which produces the calculated distance value to the measurement result of the actual distance of the gas leak position in the pipeline is 0.63% which shows the results of this study are very good.","PeriodicalId":344981,"journal":{"name":"2020 6th International Conference on Computing Engineering and Design (ICCED)","volume":"11 27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Detection of Leak Position in Household LPG Distribution Pipes Using Gas Pressure Sensors and Continuity Equation\",\"authors\":\"Anang Suryana, Mukhlis Ali, Samsul Pahmi, Muhammad Mahmud, Duddy Suherman, A. Dera, Ilham Fazrul Iman, Teja Nuralam\",\"doi\":\"10.1109/ICCED51276.2020.9415775\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Factors causing pollution both water and air and fires can be caused by the pollution of liquefied petroleum gas (LPG) that comes from gas network leaks from National gas Company (PGN) to households. For National gas Company (PGN) due to LPG gas pipeline leaks can cause quantitative losses. To prevent losses caused by LPG network leaks that are distributed to households, a gas pipeline leak detection system can be applied using the concept of fluid mechanics. Where the position of the gas pipe leakage can be known by the difference in gas pressure at the two ends of the pipe. The difference in pressure on the small gas pipe after the calculation by including the friction factor then the pipe has a leak, but if the difference is greater then the pipe is in normal condition. To detect leaks quickly, the pressure monitoring data will be monitored in a database that is displayed in front end point of the location of leakage of household gas pipes to officers who monitor the performance of the household gas pipeline. The results of this study indicate that the distance or position of the gas leak in the gas pipeline network can be measured by the difference between the two pressures at both ends of the gas pipe that is leaking. The error resulting from the reading of the pressure sensor which produces the calculated distance value to the measurement result of the actual distance of the gas leak position in the pipeline is 0.63% which shows the results of this study are very good.\",\"PeriodicalId\":344981,\"journal\":{\"name\":\"2020 6th International Conference on Computing Engineering and Design (ICCED)\",\"volume\":\"11 27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 6th International Conference on Computing Engineering and Design (ICCED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCED51276.2020.9415775\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 6th International Conference on Computing Engineering and Design (ICCED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCED51276.2020.9415775","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

导致水、空气污染和火灾的因素可能是由国家燃气公司(PGN)的燃气网络泄漏到家庭的液化石油气(LPG)污染引起的。对于国家燃气公司(PGN)来说,由于液化石油气管道泄漏会造成定量的损失。为了防止石油气管网泄漏给住户造成的损失,可以利用流体力学的概念,应用燃气管道泄漏检测系统。其中燃气管道泄漏的位置可以通过管道两端气体压力差来得知。小气体管道上的压力差计算后,包括摩擦系数,则管道有泄漏,但如果差异较大,则管道是正常状态。为了快速发现泄漏,压力监测数据会在一个数据库中进行监测,该数据库显示在家用燃气管道泄漏位置的前端,供监测家用燃气管道性能的人员使用。研究结果表明,燃气管网中气体泄漏的距离或位置可以通过燃气管道两端的两个压力差来测量。压力传感器的读数产生的计算距离值与管道中气体泄漏位置实际距离的测量结果误差为0.63%,表明本研究的结果是很好的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection of Leak Position in Household LPG Distribution Pipes Using Gas Pressure Sensors and Continuity Equation
Factors causing pollution both water and air and fires can be caused by the pollution of liquefied petroleum gas (LPG) that comes from gas network leaks from National gas Company (PGN) to households. For National gas Company (PGN) due to LPG gas pipeline leaks can cause quantitative losses. To prevent losses caused by LPG network leaks that are distributed to households, a gas pipeline leak detection system can be applied using the concept of fluid mechanics. Where the position of the gas pipe leakage can be known by the difference in gas pressure at the two ends of the pipe. The difference in pressure on the small gas pipe after the calculation by including the friction factor then the pipe has a leak, but if the difference is greater then the pipe is in normal condition. To detect leaks quickly, the pressure monitoring data will be monitored in a database that is displayed in front end point of the location of leakage of household gas pipes to officers who monitor the performance of the household gas pipeline. The results of this study indicate that the distance or position of the gas leak in the gas pipeline network can be measured by the difference between the two pressures at both ends of the gas pipe that is leaking. The error resulting from the reading of the pressure sensor which produces the calculated distance value to the measurement result of the actual distance of the gas leak position in the pipeline is 0.63% which shows the results of this study are very good.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信