{"title":"水三相点电池不确定度评定的比较测量","authors":"I. Kishimoto, K. Sato, K. Koizumi, M. Arai","doi":"10.1109/SICE.2002.1195565","DOIUrl":null,"url":null,"abstract":"Comparison measurement was performed on some triple point of water (TPW) cells, including national standard TPW cells. The purpose is to reassess the uncertainty source of realized temperatures of the TPW cells. The results showed the largest difference among them is represented as 0.036 /spl plusmn/ 0.035 mK with the coverage factor k = 2.","PeriodicalId":301855,"journal":{"name":"Proceedings of the 41st SICE Annual Conference. SICE 2002.","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison measurement of water triple point cells for uncertainty evaluation\",\"authors\":\"I. Kishimoto, K. Sato, K. Koizumi, M. Arai\",\"doi\":\"10.1109/SICE.2002.1195565\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Comparison measurement was performed on some triple point of water (TPW) cells, including national standard TPW cells. The purpose is to reassess the uncertainty source of realized temperatures of the TPW cells. The results showed the largest difference among them is represented as 0.036 /spl plusmn/ 0.035 mK with the coverage factor k = 2.\",\"PeriodicalId\":301855,\"journal\":{\"name\":\"Proceedings of the 41st SICE Annual Conference. SICE 2002.\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st SICE Annual Conference. SICE 2002.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2002.1195565\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st SICE Annual Conference. SICE 2002.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2002.1195565","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison measurement of water triple point cells for uncertainty evaluation
Comparison measurement was performed on some triple point of water (TPW) cells, including national standard TPW cells. The purpose is to reassess the uncertainty source of realized temperatures of the TPW cells. The results showed the largest difference among them is represented as 0.036 /spl plusmn/ 0.035 mK with the coverage factor k = 2.