校准之后将对肾上腺皮产生影响

Lukas Reeß, H. Dietze
{"title":"校准之后将对肾上腺皮产生影响","authors":"Lukas Reeß, H. Dietze","doi":"10.54352/dozv.rvku2118","DOIUrl":null,"url":null,"abstract":"Purpose. The aim of this study is to characterise the changes in choroidal thickness during and after a prolonged accom­ modation period using optical coherence tomography (OCT). Subjects and Methods. This study used 24 test subjects (age 28.2 ± 2.6 years), with n = 18 assigned to the moderate myopic group (MSE: ­2.6 ± 1.76 D) and n = 6 to the emmetropic group (MSE: ­0.07 ± 0.24 D). The test subjects underwent an accommodation relaxation phase (ten minutes), an accom­ modation phase (twenty minutes of continuous accommoda­ tion), and another relaxation phase (ten minutes). Seven OCT scans (Topcon Corporation, Tokyo, Japan) were taken along a horizontal axis on each eye at five­minute intervals. For each tomogram, the subfoveal, temporal and nasal choroidal thick­ ness was determined manually at three measurement points (2 mm apart) using a measurement tool. To trigger the process of accommodation, a mobile phone was attached to the side of the OCT device and the display was projected into the measurement beam path of the OCT via a semi­transparent mirror (demand of accommodation = 5.0 D). Results. During accommodation, the choroidal thickness decreased significantly by an average of ­8.06 ± 7.33 µm in the subfoveal region, ­4.00 ± 11.00 µm in the nasal region, and ­5.29 ± 12.52 µm in the temporal region (each with p < 0.01). Furthermore, emmetropic eyes showed a significantly strong­ er decrease in the subfoveal region (­13.08 ± 8.58 µm) than myopic eyes (­6.39 ± 6.06 µm). In the ten minutes following the accommodation phase, the choroid returned to its initial thickness, showing no significant difference (p = 0.80) in the degree of recovery between myopic and emmetropic eyes. Conclusion. The study shows that the process of accommo­ dation is associated with a decrease in choroidal thickness. The results further suggest that accommodation in myopic eyes entails a smaller decrease in choroidal thickness than in emmetropic eyes. The apparatus design developed spe­ cifically for this study to project a smartphone display into the measurement beam path of the OCT device is suitable for stimulating accommodation over a longer period while performing repeated OCT scans. Keywords myopia, accommodation, choroidal thickness","PeriodicalId":347784,"journal":{"name":"Optometry &amp; Contact Lenses","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Einfluss der Akkommodation auf die Aderhautdicke: eine Pilotstudie\",\"authors\":\"Lukas Reeß, H. Dietze\",\"doi\":\"10.54352/dozv.rvku2118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. The aim of this study is to characterise the changes in choroidal thickness during and after a prolonged accom­ modation period using optical coherence tomography (OCT). Subjects and Methods. This study used 24 test subjects (age 28.2 ± 2.6 years), with n = 18 assigned to the moderate myopic group (MSE: ­2.6 ± 1.76 D) and n = 6 to the emmetropic group (MSE: ­0.07 ± 0.24 D). The test subjects underwent an accommodation relaxation phase (ten minutes), an accom­ modation phase (twenty minutes of continuous accommoda­ tion), and another relaxation phase (ten minutes). Seven OCT scans (Topcon Corporation, Tokyo, Japan) were taken along a horizontal axis on each eye at five­minute intervals. For each tomogram, the subfoveal, temporal and nasal choroidal thick­ ness was determined manually at three measurement points (2 mm apart) using a measurement tool. To trigger the process of accommodation, a mobile phone was attached to the side of the OCT device and the display was projected into the measurement beam path of the OCT via a semi­transparent mirror (demand of accommodation = 5.0 D). Results. During accommodation, the choroidal thickness decreased significantly by an average of ­8.06 ± 7.33 µm in the subfoveal region, ­4.00 ± 11.00 µm in the nasal region, and ­5.29 ± 12.52 µm in the temporal region (each with p < 0.01). Furthermore, emmetropic eyes showed a significantly strong­ er decrease in the subfoveal region (­13.08 ± 8.58 µm) than myopic eyes (­6.39 ± 6.06 µm). In the ten minutes following the accommodation phase, the choroid returned to its initial thickness, showing no significant difference (p = 0.80) in the degree of recovery between myopic and emmetropic eyes. Conclusion. The study shows that the process of accommo­ dation is associated with a decrease in choroidal thickness. The results further suggest that accommodation in myopic eyes entails a smaller decrease in choroidal thickness than in emmetropic eyes. The apparatus design developed spe­ cifically for this study to project a smartphone display into the measurement beam path of the OCT device is suitable for stimulating accommodation over a longer period while performing repeated OCT scans. Keywords myopia, accommodation, choroidal thickness\",\"PeriodicalId\":347784,\"journal\":{\"name\":\"Optometry &amp; Contact Lenses\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optometry &amp; Contact Lenses\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54352/dozv.rvku2118\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optometry &amp; Contact Lenses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54352/dozv.rvku2118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的。本研究的目的是利用光学相干断层扫描(OCT)表征在长时间调节期间和之后脉络膜厚度的变化。研究对象和方法。本研究共纳入24例受试者(年龄28.2±2.6岁),其中中度近视组(MSE: - 2.6±1.76 D) 18例,准斜视组(MSE: - 0.07±0.24 D) 6例,受试者分别经历调节放松阶段(10分钟)、调节-调节阶段(20分钟连续调节)和放松阶段(10分钟)。每隔5分钟沿水平轴对每只眼睛进行7次OCT扫描(Topcon Corporation, Tokyo, Japan)。对于每张断层图,使用测量工具在三个测量点(相距2mm)手动确定中央凹下、颞部和鼻脉络膜厚度。为了触发调节过程,将手机固定在OCT设备的侧面,显示器通过半透明镜子投射到OCT的测量光束路径中(调节需求= 5.0 D)。调节过程中,中央凹下区脉络膜厚度平均下降-8.06±7.33µm,鼻区下降-4.00±11.00µm,颞区下降-5.29±12.52µm(均p < 0.01)。此外,远视眼的中央凹下区- er下降幅度(- 13.08±8.58µm)明显高于近视眼(- 6.39±6.06µm)。调节期后10分钟,脉络膜恢复到初始厚度,近视眼和远视眼的恢复程度无显著差异(p = 0.80)。结论。研究表明,调节过程与脉络膜厚度的减少有关。结果进一步表明,与远视眼相比,近视眼的调节导致脉络膜厚度的减少较小。专门为本研究开发的设备将智能手机显示器投射到OCT设备的测量光束路径中,适合在执行重复OCT扫描时长时间刺激调节。关键词近视;调节;脉络膜厚度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Einfluss der Akkommodation auf die Aderhautdicke: eine Pilotstudie
Purpose. The aim of this study is to characterise the changes in choroidal thickness during and after a prolonged accom­ modation period using optical coherence tomography (OCT). Subjects and Methods. This study used 24 test subjects (age 28.2 ± 2.6 years), with n = 18 assigned to the moderate myopic group (MSE: ­2.6 ± 1.76 D) and n = 6 to the emmetropic group (MSE: ­0.07 ± 0.24 D). The test subjects underwent an accommodation relaxation phase (ten minutes), an accom­ modation phase (twenty minutes of continuous accommoda­ tion), and another relaxation phase (ten minutes). Seven OCT scans (Topcon Corporation, Tokyo, Japan) were taken along a horizontal axis on each eye at five­minute intervals. For each tomogram, the subfoveal, temporal and nasal choroidal thick­ ness was determined manually at three measurement points (2 mm apart) using a measurement tool. To trigger the process of accommodation, a mobile phone was attached to the side of the OCT device and the display was projected into the measurement beam path of the OCT via a semi­transparent mirror (demand of accommodation = 5.0 D). Results. During accommodation, the choroidal thickness decreased significantly by an average of ­8.06 ± 7.33 µm in the subfoveal region, ­4.00 ± 11.00 µm in the nasal region, and ­5.29 ± 12.52 µm in the temporal region (each with p < 0.01). Furthermore, emmetropic eyes showed a significantly strong­ er decrease in the subfoveal region (­13.08 ± 8.58 µm) than myopic eyes (­6.39 ± 6.06 µm). In the ten minutes following the accommodation phase, the choroid returned to its initial thickness, showing no significant difference (p = 0.80) in the degree of recovery between myopic and emmetropic eyes. Conclusion. The study shows that the process of accommo­ dation is associated with a decrease in choroidal thickness. The results further suggest that accommodation in myopic eyes entails a smaller decrease in choroidal thickness than in emmetropic eyes. The apparatus design developed spe­ cifically for this study to project a smartphone display into the measurement beam path of the OCT device is suitable for stimulating accommodation over a longer period while performing repeated OCT scans. Keywords myopia, accommodation, choroidal thickness
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信