{"title":"具有无功补偿功能的单相并网轴向磁通永磁发电机系统","authors":"P. Wannakarn, V. Kinnares","doi":"10.1109/ASSCC.2012.6523289","DOIUrl":null,"url":null,"abstract":"This paper presents a single-phase grid connected system with reactive power compensation functionality for an axial flux permanent magnet (AFPM) generator. The proposed system offers bi-function namely not only transfers energy generated by any kind of mechanical power sources via an AFPM but also feeds reactive power to compensate the reactive power drawn by loads. The proposed system includes 3 main parts: the 5-Phase laboratory made AC AFPM, full bridge rectifier and an IGBT full bridge inverter. A current control technique based on fixed hysteresis band is used. All control algorithms are implemented on dsPIC30F4011 Digital Signal Controller (DSC). The proposed system is able to transfer energy supplied from the proposed AFPM to a 1-phase, 50 Hz, 220 V mains supply. Apart from the power transfer, the proposed system also provides reactive power compensation for resistive-inductive load to improve power factor of the grid to nearly unity. The system performance is investigated which appears satisfactory.","PeriodicalId":341348,"journal":{"name":"2012 10th International Power & Energy Conference (IPEC)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Single-phase grid connected axial flux permanent magnet generator system with reactive power compensation functionality\",\"authors\":\"P. Wannakarn, V. Kinnares\",\"doi\":\"10.1109/ASSCC.2012.6523289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a single-phase grid connected system with reactive power compensation functionality for an axial flux permanent magnet (AFPM) generator. The proposed system offers bi-function namely not only transfers energy generated by any kind of mechanical power sources via an AFPM but also feeds reactive power to compensate the reactive power drawn by loads. The proposed system includes 3 main parts: the 5-Phase laboratory made AC AFPM, full bridge rectifier and an IGBT full bridge inverter. A current control technique based on fixed hysteresis band is used. All control algorithms are implemented on dsPIC30F4011 Digital Signal Controller (DSC). The proposed system is able to transfer energy supplied from the proposed AFPM to a 1-phase, 50 Hz, 220 V mains supply. Apart from the power transfer, the proposed system also provides reactive power compensation for resistive-inductive load to improve power factor of the grid to nearly unity. The system performance is investigated which appears satisfactory.\",\"PeriodicalId\":341348,\"journal\":{\"name\":\"2012 10th International Power & Energy Conference (IPEC)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 10th International Power & Energy Conference (IPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2012.6523289\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th International Power & Energy Conference (IPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2012.6523289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

提出了一种具有轴向磁通永磁发电机无功补偿功能的单相并网系统。所提出的系统具有双重功能,即不仅通过AFPM传输任何类型的机械电源产生的能量,而且还提供无功功率来补偿负载所吸收的无功功率。该系统包括3个主要部分:5相实验室制造的交流AFPM、全桥整流器和IGBT全桥逆变器。采用了一种基于固定磁滞带的电流控制技术。所有控制算法均在dsPIC30F4011数字信号控制器(DSC)上实现。所提出的系统能够将所提出的AFPM提供的能量传输到单相,50 Hz, 220 V电源。该系统除实现电力传输外,还对阻感性负荷进行无功补偿,使电网的功率因数接近统一。对系统的性能进行了测试,结果令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Single-phase grid connected axial flux permanent magnet generator system with reactive power compensation functionality
This paper presents a single-phase grid connected system with reactive power compensation functionality for an axial flux permanent magnet (AFPM) generator. The proposed system offers bi-function namely not only transfers energy generated by any kind of mechanical power sources via an AFPM but also feeds reactive power to compensate the reactive power drawn by loads. The proposed system includes 3 main parts: the 5-Phase laboratory made AC AFPM, full bridge rectifier and an IGBT full bridge inverter. A current control technique based on fixed hysteresis band is used. All control algorithms are implemented on dsPIC30F4011 Digital Signal Controller (DSC). The proposed system is able to transfer energy supplied from the proposed AFPM to a 1-phase, 50 Hz, 220 V mains supply. Apart from the power transfer, the proposed system also provides reactive power compensation for resistive-inductive load to improve power factor of the grid to nearly unity. The system performance is investigated which appears satisfactory.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信