{"title":"行走时施加中外侧全身振动装置的研制","authors":"M. G. Naón, S. Marelli, A. P. Moorhead, B. Saggin, G. Moschioni, M. Tarabini","doi":"10.1109/MeMeA52024.2021.9478701","DOIUrl":null,"url":null,"abstract":"A compact and light-weight set-up to impose medio-lateral vibration while walking has been designed and manufactured. A vibrating plate was actuated by a motor and a linear guide. After the design and finite-element analysis, the set-up has been manufactured and tested in the frequency band 0.5-4 Hz with amplitude below ± 20 mm, that is compatible for human testing. Total harmonic distortion has been measured below −30 dB. Crosstalk values along Z and Y measured at the corners of the moving platform were lower than 0.1 at 4 Hz. Given the previous analyses, the set-up can be used to test in a movement laboratory the effect of vibration during walking, mounting a walking pad on the platform.","PeriodicalId":429222,"journal":{"name":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a device to impose medio-lateral whole-body vibration while walking\",\"authors\":\"M. G. Naón, S. Marelli, A. P. Moorhead, B. Saggin, G. Moschioni, M. Tarabini\",\"doi\":\"10.1109/MeMeA52024.2021.9478701\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A compact and light-weight set-up to impose medio-lateral vibration while walking has been designed and manufactured. A vibrating plate was actuated by a motor and a linear guide. After the design and finite-element analysis, the set-up has been manufactured and tested in the frequency band 0.5-4 Hz with amplitude below ± 20 mm, that is compatible for human testing. Total harmonic distortion has been measured below −30 dB. Crosstalk values along Z and Y measured at the corners of the moving platform were lower than 0.1 at 4 Hz. Given the previous analyses, the set-up can be used to test in a movement laboratory the effect of vibration during walking, mounting a walking pad on the platform.\",\"PeriodicalId\":429222,\"journal\":{\"name\":\"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA52024.2021.9478701\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA52024.2021.9478701","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

设计和制造了一种紧凑轻便的装置,可以在行走时施加中侧向振动。振动板由电机和直线导轨驱动。经过设计和有限元分析,该装置已制造并在0.5- 4hz频段内进行了测试,振幅低于±20 mm,可用于人体测试。总谐波失真测量值低于−30db。在移动平台的四角处测得的沿Z和Y方向的串扰值在4 Hz时均小于0.1。考虑到之前的分析,该装置可用于在运动实验室中测试行走时振动的影响,在平台上安装一个行走垫。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a device to impose medio-lateral whole-body vibration while walking
A compact and light-weight set-up to impose medio-lateral vibration while walking has been designed and manufactured. A vibrating plate was actuated by a motor and a linear guide. After the design and finite-element analysis, the set-up has been manufactured and tested in the frequency band 0.5-4 Hz with amplitude below ± 20 mm, that is compatible for human testing. Total harmonic distortion has been measured below −30 dB. Crosstalk values along Z and Y measured at the corners of the moving platform were lower than 0.1 at 4 Hz. Given the previous analyses, the set-up can be used to test in a movement laboratory the effect of vibration during walking, mounting a walking pad on the platform.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信