犬股骨骨折修复6年后关节镜下螺丝刀碎片去除

VCOT Open Pub Date : 2020-01-01 DOI:10.1055/s-0040-1709451
M. Petazzoni
{"title":"犬股骨骨折修复6年后关节镜下螺丝刀碎片去除","authors":"M. Petazzoni","doi":"10.1055/s-0040-1709451","DOIUrl":null,"url":null,"abstract":"Abstract Objective The aim of this study was to report an unusual case of an iatrogenic foreign body within the stifle joint, removed 6 years after distal femoral fracture repair in a small dog. Acute lameness was caused by a migrating screwdriver fragment, which had been lost during initial fracture repair and which did not cause clinical signs for years until dislodged inside the joint. Case Report A male Jack Russell, 7 years of age, underwent plate and screws fixation to treat a Salter-Harris type I fracture at the age of 9 months. Seven months after surgery, partial implant removal was performed. Six years after fracture repair, the dog presented for a non-weight-bearing lameness and pain on the previously operated stifle joint, which occurred suddenly while walking on the leash. Radiographs revealed a small intra-articular metallic radiodense foreign body. Arthroscopy was used to remove the migrating broken-tip of a screwdriver from the medial aspect of the tibiofemoral joint. Retrieving the foreign body led to the immediate resolution of clinical signs without complications. Conclusion By reporting this case of a forgotten foreign body retained inside a stifle joint for 6 years, we aim to illustrate the potential risk of leaving a piece of metal inside the body. A high index of suspicion for such complications should be kept a long time after surgery. Arthroscopy was a useful first-line tool for efficiently and mini-invasively treating this unusual problem.","PeriodicalId":443672,"journal":{"name":"VCOT Open","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Arthroscopic Removal of a Screwdriver Fragment in a Dog 6 Years after Femoral Fracture Repair\",\"authors\":\"M. Petazzoni\",\"doi\":\"10.1055/s-0040-1709451\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objective The aim of this study was to report an unusual case of an iatrogenic foreign body within the stifle joint, removed 6 years after distal femoral fracture repair in a small dog. Acute lameness was caused by a migrating screwdriver fragment, which had been lost during initial fracture repair and which did not cause clinical signs for years until dislodged inside the joint. Case Report A male Jack Russell, 7 years of age, underwent plate and screws fixation to treat a Salter-Harris type I fracture at the age of 9 months. Seven months after surgery, partial implant removal was performed. Six years after fracture repair, the dog presented for a non-weight-bearing lameness and pain on the previously operated stifle joint, which occurred suddenly while walking on the leash. Radiographs revealed a small intra-articular metallic radiodense foreign body. Arthroscopy was used to remove the migrating broken-tip of a screwdriver from the medial aspect of the tibiofemoral joint. Retrieving the foreign body led to the immediate resolution of clinical signs without complications. Conclusion By reporting this case of a forgotten foreign body retained inside a stifle joint for 6 years, we aim to illustrate the potential risk of leaving a piece of metal inside the body. A high index of suspicion for such complications should be kept a long time after surgery. Arthroscopy was a useful first-line tool for efficiently and mini-invasively treating this unusual problem.\",\"PeriodicalId\":443672,\"journal\":{\"name\":\"VCOT Open\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"VCOT Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0040-1709451\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"VCOT Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0040-1709451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

摘要目的报告一例罕见的犬股远端骨折修复后6年取出的膝关节内医源性异物。急性跛行是由一个迁移的螺丝刀碎片引起的,该碎片在最初的骨折修复过程中丢失,多年来没有引起临床症状,直到在关节内移位。病例报告一名7岁的雄性杰克罗素犬,在9个月大时接受钢板和螺钉固定治疗Salter-Harris I型骨折。术后7个月,进行部分种植体移除。骨折修复六年后,狗出现了非负重的跛行和先前手术的膝关节疼痛,这是在牵着皮带走路时突然发生的。x线片显示一个小的关节内金属放射性致密异物。关节镜用于从胫股关节内侧移除迁移的螺丝刀断裂尖端。取出异物可立即消除临床症状,无并发症。结论:通过报告这个被遗忘的异物在膝关节内保留了6年的病例,我们的目的是说明在体内留下一块金属的潜在风险。术后应长期保持对此类并发症的高度怀疑。关节镜检查是有效微创治疗这种罕见疾病的一线工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Arthroscopic Removal of a Screwdriver Fragment in a Dog 6 Years after Femoral Fracture Repair
Abstract Objective The aim of this study was to report an unusual case of an iatrogenic foreign body within the stifle joint, removed 6 years after distal femoral fracture repair in a small dog. Acute lameness was caused by a migrating screwdriver fragment, which had been lost during initial fracture repair and which did not cause clinical signs for years until dislodged inside the joint. Case Report A male Jack Russell, 7 years of age, underwent plate and screws fixation to treat a Salter-Harris type I fracture at the age of 9 months. Seven months after surgery, partial implant removal was performed. Six years after fracture repair, the dog presented for a non-weight-bearing lameness and pain on the previously operated stifle joint, which occurred suddenly while walking on the leash. Radiographs revealed a small intra-articular metallic radiodense foreign body. Arthroscopy was used to remove the migrating broken-tip of a screwdriver from the medial aspect of the tibiofemoral joint. Retrieving the foreign body led to the immediate resolution of clinical signs without complications. Conclusion By reporting this case of a forgotten foreign body retained inside a stifle joint for 6 years, we aim to illustrate the potential risk of leaving a piece of metal inside the body. A high index of suspicion for such complications should be kept a long time after surgery. Arthroscopy was a useful first-line tool for efficiently and mini-invasively treating this unusual problem.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信