气体(SF6)绝缘变电站高压试验

C. JohnDeBritto
{"title":"气体(SF6)绝缘变电站高压试验","authors":"C. JohnDeBritto","doi":"10.21013/JTE.V4.N1.P4","DOIUrl":null,"url":null,"abstract":"A resonant test system with variable frequency has been used to perform the On-Site Testing. The paper mainly describes about the concept of High Voltage testing using resonant test system with variable frequency and the concept of high voltage fault sensing and tripping mechanism. A design of a 220 V switchgear arrangement is described and performance of high voltage testing is explained. A fault sensing circuit along the arrangement has also been briefed.","PeriodicalId":269688,"journal":{"name":"IRA-International Journal of Technology & Engineering","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High Voltage Testing of Gas (SF6) Insulated Substation\",\"authors\":\"C. JohnDeBritto\",\"doi\":\"10.21013/JTE.V4.N1.P4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A resonant test system with variable frequency has been used to perform the On-Site Testing. The paper mainly describes about the concept of High Voltage testing using resonant test system with variable frequency and the concept of high voltage fault sensing and tripping mechanism. A design of a 220 V switchgear arrangement is described and performance of high voltage testing is explained. A fault sensing circuit along the arrangement has also been briefed.\",\"PeriodicalId\":269688,\"journal\":{\"name\":\"IRA-International Journal of Technology & Engineering\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IRA-International Journal of Technology & Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21013/JTE.V4.N1.P4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IRA-International Journal of Technology & Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21013/JTE.V4.N1.P4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用变频谐振测试系统进行了现场测试。本文主要介绍了采用变频谐振测试系统进行高压测试的概念和高压故障检测跳闸机构的概念。介绍了一种220v开关柜的布置设计,并对高压试验的性能进行了说明。此外,还介绍了沿该装置安装的故障感应电路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High Voltage Testing of Gas (SF6) Insulated Substation
A resonant test system with variable frequency has been used to perform the On-Site Testing. The paper mainly describes about the concept of High Voltage testing using resonant test system with variable frequency and the concept of high voltage fault sensing and tripping mechanism. A design of a 220 V switchgear arrangement is described and performance of high voltage testing is explained. A fault sensing circuit along the arrangement has also been briefed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信