{"title":"基于心电图的阻塞性睡眠呼吸暂停诊断","authors":"Muhammad Jawad Ghafoor, Sajid Ahmed, K. Riaz","doi":"10.1109/INTELLECT55495.2022.9969183","DOIUrl":null,"url":null,"abstract":"Obstructive sleep apnea (OSA) is a sleeping disorder in which the breathing of a person stops and starts multiple times during sleep. In this process, to automatically diagnose the presence of OSA, a simple, fast, and low cost technique is proposed. In the proposed technique, discrete-Fourier-transform (DFT) is applied to the noise and artifacts free electrocardiograph (ECG) signal. The proposed technique is validated over 260 ECG signals from the PhysioNet database. It is found that compared to polysomnography, which study of sleep profile of a patient and is a long, disturbing, and costly technique, proposed technique performs much better. The accuracy, specificity, and sensitivity of the proposed technique is 98.56%, 97.89%, 99.26% respectively.","PeriodicalId":219188,"journal":{"name":"2022 Third International Conference on Latest trends in Electrical Engineering and Computing Technologies (INTELLECT)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Electrocardiograph Based Obstructive Sleep Apnea Diagnoses\",\"authors\":\"Muhammad Jawad Ghafoor, Sajid Ahmed, K. Riaz\",\"doi\":\"10.1109/INTELLECT55495.2022.9969183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Obstructive sleep apnea (OSA) is a sleeping disorder in which the breathing of a person stops and starts multiple times during sleep. In this process, to automatically diagnose the presence of OSA, a simple, fast, and low cost technique is proposed. In the proposed technique, discrete-Fourier-transform (DFT) is applied to the noise and artifacts free electrocardiograph (ECG) signal. The proposed technique is validated over 260 ECG signals from the PhysioNet database. It is found that compared to polysomnography, which study of sleep profile of a patient and is a long, disturbing, and costly technique, proposed technique performs much better. The accuracy, specificity, and sensitivity of the proposed technique is 98.56%, 97.89%, 99.26% respectively.\",\"PeriodicalId\":219188,\"journal\":{\"name\":\"2022 Third International Conference on Latest trends in Electrical Engineering and Computing Technologies (INTELLECT)\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Third International Conference on Latest trends in Electrical Engineering and Computing Technologies (INTELLECT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTELLECT55495.2022.9969183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Third International Conference on Latest trends in Electrical Engineering and Computing Technologies (INTELLECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTELLECT55495.2022.9969183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

阻塞性睡眠呼吸暂停(OSA)是一种睡眠障碍,患者在睡眠中多次呼吸停止和开始。在此过程中,提出了一种简单、快速、低成本的自动诊断OSA的方法。在该技术中,离散傅立叶变换(DFT)应用于无噪声和伪影的心电信号。通过对来自PhysioNet数据库的260个心电信号进行验证。研究发现,与多导睡眠描记术相比,多导睡眠描记术的效果要好得多。该方法的准确度为98.56%,特异度为97.89%,灵敏度为99.26%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrocardiograph Based Obstructive Sleep Apnea Diagnoses
Obstructive sleep apnea (OSA) is a sleeping disorder in which the breathing of a person stops and starts multiple times during sleep. In this process, to automatically diagnose the presence of OSA, a simple, fast, and low cost technique is proposed. In the proposed technique, discrete-Fourier-transform (DFT) is applied to the noise and artifacts free electrocardiograph (ECG) signal. The proposed technique is validated over 260 ECG signals from the PhysioNet database. It is found that compared to polysomnography, which study of sleep profile of a patient and is a long, disturbing, and costly technique, proposed technique performs much better. The accuracy, specificity, and sensitivity of the proposed technique is 98.56%, 97.89%, 99.26% respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信