{"title":"基于过采样技术的蒸发量数字测量","authors":"Shahriar Alipour, Paknoosh Karim Aghaee","doi":"10.1109/ICCIAUTOM.2013.6912836","DOIUrl":null,"url":null,"abstract":"This article describes a system which performs a measurement task by controlling water level in an evaporation measuring setup. This measurement is inherently digital and the intelligent controller performs noise reduction and disturbance compensation. This measurement is based on oversampling for better noise shaping and increase in measurement accuracy. The proposed structure is implemented and the experimental results are satisfactory in terms of accuracy of measurement, according to the need in hydrological studies.","PeriodicalId":444883,"journal":{"name":"The 3rd International Conference on Control, Instrumentation, and Automation","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Digital measurement of evaporation based on oversampling technique\",\"authors\":\"Shahriar Alipour, Paknoosh Karim Aghaee\",\"doi\":\"10.1109/ICCIAUTOM.2013.6912836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article describes a system which performs a measurement task by controlling water level in an evaporation measuring setup. This measurement is inherently digital and the intelligent controller performs noise reduction and disturbance compensation. This measurement is based on oversampling for better noise shaping and increase in measurement accuracy. The proposed structure is implemented and the experimental results are satisfactory in terms of accuracy of measurement, according to the need in hydrological studies.\",\"PeriodicalId\":444883,\"journal\":{\"name\":\"The 3rd International Conference on Control, Instrumentation, and Automation\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 3rd International Conference on Control, Instrumentation, and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCIAUTOM.2013.6912836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 3rd International Conference on Control, Instrumentation, and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCIAUTOM.2013.6912836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Digital measurement of evaporation based on oversampling technique
This article describes a system which performs a measurement task by controlling water level in an evaporation measuring setup. This measurement is inherently digital and the intelligent controller performs noise reduction and disturbance compensation. This measurement is based on oversampling for better noise shaping and increase in measurement accuracy. The proposed structure is implemented and the experimental results are satisfactory in terms of accuracy of measurement, according to the need in hydrological studies.