利用UPFC可控性措施抑制低频振荡

G. Kannayeram, N. Prakash, P. Eswari Prabha, R. K. Gobiga
{"title":"利用UPFC可控性措施抑制低频振荡","authors":"G. Kannayeram, N. Prakash, P. Eswari Prabha, R. K. Gobiga","doi":"10.1109/ICRAECC43874.2019.8995008","DOIUrl":null,"url":null,"abstract":"In immense scale, interconnected power system develops numerous unique issues, for example, low modern frequency oscillations because of the absence of damping of the mechanical oscillations of the system. Power System Stabilizers (PSS) have been utilized in decades ago, to effectively enhance control framework damping to low modern frequency oscillations. Bound together Unified Power Flow Controller (UPFC) is a multi-functional FACTS (Flexible AC Transmission Systems) controller with the essential capacity of intensity stream control and auxiliary obligations of voltage support, transient dependability improvement and wavering damping and so forth. Be that as it may, the essential control work inside the UPFC, the voltage control of the DC interface capacitor communicates adversely with the PSS introduced in the framework along these lines harming the framework wavering dependability. Along these lines an input valuable control, notwithstanding the FACTS gadget essential control is recommended to get the altered Phillips-Heffron straight model. Singular Value Decomposition (SVD) is utilized to pick the signal that is most appropriate for damping the electro-mechanical oscillations. Eigen value examination and non-linear simulation are utilized to evaluate the effectiveness of the power system","PeriodicalId":137313,"journal":{"name":"2019 International Conference on Recent Advances in Energy-efficient Computing and Communication (ICRAECC)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Damping of Low Frequency Oscillations Using Controllability Measures of UPFC\",\"authors\":\"G. Kannayeram, N. Prakash, P. Eswari Prabha, R. K. Gobiga\",\"doi\":\"10.1109/ICRAECC43874.2019.8995008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In immense scale, interconnected power system develops numerous unique issues, for example, low modern frequency oscillations because of the absence of damping of the mechanical oscillations of the system. Power System Stabilizers (PSS) have been utilized in decades ago, to effectively enhance control framework damping to low modern frequency oscillations. Bound together Unified Power Flow Controller (UPFC) is a multi-functional FACTS (Flexible AC Transmission Systems) controller with the essential capacity of intensity stream control and auxiliary obligations of voltage support, transient dependability improvement and wavering damping and so forth. Be that as it may, the essential control work inside the UPFC, the voltage control of the DC interface capacitor communicates adversely with the PSS introduced in the framework along these lines harming the framework wavering dependability. Along these lines an input valuable control, notwithstanding the FACTS gadget essential control is recommended to get the altered Phillips-Heffron straight model. Singular Value Decomposition (SVD) is utilized to pick the signal that is most appropriate for damping the electro-mechanical oscillations. Eigen value examination and non-linear simulation are utilized to evaluate the effectiveness of the power system\",\"PeriodicalId\":137313,\"journal\":{\"name\":\"2019 International Conference on Recent Advances in Energy-efficient Computing and Communication (ICRAECC)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Recent Advances in Energy-efficient Computing and Communication (ICRAECC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRAECC43874.2019.8995008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Recent Advances in Energy-efficient Computing and Communication (ICRAECC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRAECC43874.2019.8995008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在巨大的规模下,互联电力系统发展出许多独特的问题,例如,由于缺乏对系统机械振荡的阻尼,导致了低现代频率振荡。电力系统稳定器(PSS)在几十年前就被用于有效地增强控制框架对低频振荡的阻尼。统一潮流控制器(UPFC)是一种多功能的柔性交流输电系统(FACTS)控制器,具有强度流控制的基本功能和电压支持、暂态可靠性改善和振荡阻尼等辅助功能。尽管如此,UPFC内部的基本控制工作,直流接口电容器的电压控制与框架中引入的PSS沿着这些线路进行不利通信,从而损害框架的可靠性。沿着这些路线,一个输入有价值的控制,尽管事实小工具的基本控制,建议得到改变的philips - heffron直模型。利用奇异值分解(SVD)提取最适合抑制机电振荡的信号。利用特征值检验和非线性仿真对电力系统的有效性进行了评价
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Damping of Low Frequency Oscillations Using Controllability Measures of UPFC
In immense scale, interconnected power system develops numerous unique issues, for example, low modern frequency oscillations because of the absence of damping of the mechanical oscillations of the system. Power System Stabilizers (PSS) have been utilized in decades ago, to effectively enhance control framework damping to low modern frequency oscillations. Bound together Unified Power Flow Controller (UPFC) is a multi-functional FACTS (Flexible AC Transmission Systems) controller with the essential capacity of intensity stream control and auxiliary obligations of voltage support, transient dependability improvement and wavering damping and so forth. Be that as it may, the essential control work inside the UPFC, the voltage control of the DC interface capacitor communicates adversely with the PSS introduced in the framework along these lines harming the framework wavering dependability. Along these lines an input valuable control, notwithstanding the FACTS gadget essential control is recommended to get the altered Phillips-Heffron straight model. Singular Value Decomposition (SVD) is utilized to pick the signal that is most appropriate for damping the electro-mechanical oscillations. Eigen value examination and non-linear simulation are utilized to evaluate the effectiveness of the power system
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信