宾夕法尼亚州立大学心室辅助装置的能量损失

M.A. Rawhouser, J. Gardner, D. Geselowitz
{"title":"宾夕法尼亚州立大学心室辅助装置的能量损失","authors":"M.A. Rawhouser, J. Gardner, D. Geselowitz","doi":"10.1109/IEMBS.1991.684906","DOIUrl":null,"url":null,"abstract":"The objective of this study was to investigate and quantify electronic and mechanical losses in the Penn State Electric Ventricular Assist Device (EVAD) and to improve the mathematical model of the EVAD. Previous studies of the Electric Total Artificial Heart (TAH) estimated power distribution in the device[l]. This study involved more detailed investigation of the motor electronics. Results show that elecrronic losses account for approximately 20% of the energy delivered to the motor during each stroke and that other motor losses account for another 55% of the total. The value of effective armature resistance was shown to be dependent on pulse width duty cycle.","PeriodicalId":297811,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Energy Losses In The Penn State Electric Ventricular Assist Device\",\"authors\":\"M.A. Rawhouser, J. Gardner, D. Geselowitz\",\"doi\":\"10.1109/IEMBS.1991.684906\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this study was to investigate and quantify electronic and mechanical losses in the Penn State Electric Ventricular Assist Device (EVAD) and to improve the mathematical model of the EVAD. Previous studies of the Electric Total Artificial Heart (TAH) estimated power distribution in the device[l]. This study involved more detailed investigation of the motor electronics. Results show that elecrronic losses account for approximately 20% of the energy delivered to the motor during each stroke and that other motor losses account for another 55% of the total. The value of effective armature resistance was shown to be dependent on pulse width duty cycle.\",\"PeriodicalId\":297811,\"journal\":{\"name\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991\",\"volume\":\"82 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1991.684906\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1991.684906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是调查和量化宾夕法尼亚州立大学电子心室辅助装置(EVAD)的电子和机械损失,并改进EVAD的数学模型。先前对全电人工心脏(Electric Total Artificial Heart, TAH)的研究估计了该装置的功率分布[1]。这项研究包括对电机电子器件进行更详细的调查。结果表明,在每次冲程中,电子损耗约占传递给电机的能量的20%,而其他电机损耗又占总能量的55%。电枢有效电阻值与脉宽占空比有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Energy Losses In The Penn State Electric Ventricular Assist Device
The objective of this study was to investigate and quantify electronic and mechanical losses in the Penn State Electric Ventricular Assist Device (EVAD) and to improve the mathematical model of the EVAD. Previous studies of the Electric Total Artificial Heart (TAH) estimated power distribution in the device[l]. This study involved more detailed investigation of the motor electronics. Results show that elecrronic losses account for approximately 20% of the energy delivered to the motor during each stroke and that other motor losses account for another 55% of the total. The value of effective armature resistance was shown to be dependent on pulse width duty cycle.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信