{"title":"使用同步相量测量的动态线路参数估计","authors":"A. Hettiarachchige-Don, V. Aravinthan, W. Jewell, S. Westervelt","doi":"10.1109/ICIAFS.2016.7946567","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel methodology for the calculation and estimation of transmission line impedance with the use of real time data from synchrophasor measurement units. Current synchrophasor standards do not provide impedance data and must therefore be calculated. The algorithms used in this paper include impedance calculation, outlier detection and elimination as well as denoising using regularized least square estimation. The proposed methodology operates using a small sample size and can therefore be applied in real time to provide operators with instantaneous impedance values from transmission lines. The paper also investigates how changing several methodology parameters can affect the accuracy of the output obtained. The overall methodology as well as these parameters have been tested using real synchrophasor data from an American utility provider.","PeriodicalId":237290,"journal":{"name":"2016 IEEE International Conference on Information and Automation for Sustainability (ICIAfS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dynamic line parameter estimation using Synchrophasor Measurements\",\"authors\":\"A. Hettiarachchige-Don, V. Aravinthan, W. Jewell, S. Westervelt\",\"doi\":\"10.1109/ICIAFS.2016.7946567\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel methodology for the calculation and estimation of transmission line impedance with the use of real time data from synchrophasor measurement units. Current synchrophasor standards do not provide impedance data and must therefore be calculated. The algorithms used in this paper include impedance calculation, outlier detection and elimination as well as denoising using regularized least square estimation. The proposed methodology operates using a small sample size and can therefore be applied in real time to provide operators with instantaneous impedance values from transmission lines. The paper also investigates how changing several methodology parameters can affect the accuracy of the output obtained. The overall methodology as well as these parameters have been tested using real synchrophasor data from an American utility provider.\",\"PeriodicalId\":237290,\"journal\":{\"name\":\"2016 IEEE International Conference on Information and Automation for Sustainability (ICIAfS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Information and Automation for Sustainability (ICIAfS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIAFS.2016.7946567\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Information and Automation for Sustainability (ICIAfS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIAFS.2016.7946567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种利用同步相量测量装置的实时数据计算和估计传输线阻抗的新方法。目前的同步相量标准不提供阻抗数据,因此必须计算。本文使用的算法包括阻抗计算、异常值检测和消除以及正则化最小二乘估计去噪。所提出的方法使用小样本量,因此可以实时应用,为操作员提供传输线的瞬时阻抗值。本文还探讨了改变几个方法学参数如何影响得到的输出精度。整体方法以及这些参数已经使用来自美国公用事业供应商的真实同步数据进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic line parameter estimation using Synchrophasor Measurements
This paper proposes a novel methodology for the calculation and estimation of transmission line impedance with the use of real time data from synchrophasor measurement units. Current synchrophasor standards do not provide impedance data and must therefore be calculated. The algorithms used in this paper include impedance calculation, outlier detection and elimination as well as denoising using regularized least square estimation. The proposed methodology operates using a small sample size and can therefore be applied in real time to provide operators with instantaneous impedance values from transmission lines. The paper also investigates how changing several methodology parameters can affect the accuracy of the output obtained. The overall methodology as well as these parameters have been tested using real synchrophasor data from an American utility provider.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信