基于有限元仿真的有源植入式医疗器械在4G和5G Sub-6频段的电磁干扰特性评估

Takuji Nishikawa, T. Hikage, M. Yamamoto
{"title":"基于有限元仿真的有源植入式医疗器械在4G和5G Sub-6频段的电磁干扰特性评估","authors":"Takuji Nishikawa, T. Hikage, M. Yamamoto","doi":"10.1109/iWEM52897.2022.9993550","DOIUrl":null,"url":null,"abstract":"This study aims to develop a method to evaluate the electromagnetic interference (EMI) characteristics of implantable medical devices (implantable cardiac pacemakers/implantable cardioverter-defibrillators) with respect to various radio wave-using devices using electromagnetic field simulation. In this paper, the relationship between EMI characteristics of implantable medical devices and RF frequencies under near-field and far-field exposure conditions was investigated through numerical simulations. As a numerical model, an implantable pacemaker embedded in a human phantom used in the EMI evaluation test is prepared, and the AIMD-EMI characteristics near the transmitter in the 4G and 5G Sub6 frequency bands are analyzed by electromagnetic field simulation based on the finite element method.","PeriodicalId":433151,"journal":{"name":"2022 IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition (iWEM)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Using FEM Simulation to Estimation of Active Implantable Medical Device EMI Characteristic in the 4G and 5G Sub-6 Frequency Bands\",\"authors\":\"Takuji Nishikawa, T. Hikage, M. Yamamoto\",\"doi\":\"10.1109/iWEM52897.2022.9993550\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims to develop a method to evaluate the electromagnetic interference (EMI) characteristics of implantable medical devices (implantable cardiac pacemakers/implantable cardioverter-defibrillators) with respect to various radio wave-using devices using electromagnetic field simulation. In this paper, the relationship between EMI characteristics of implantable medical devices and RF frequencies under near-field and far-field exposure conditions was investigated through numerical simulations. As a numerical model, an implantable pacemaker embedded in a human phantom used in the EMI evaluation test is prepared, and the AIMD-EMI characteristics near the transmitter in the 4G and 5G Sub6 frequency bands are analyzed by electromagnetic field simulation based on the finite element method.\",\"PeriodicalId\":433151,\"journal\":{\"name\":\"2022 IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition (iWEM)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition (iWEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iWEM52897.2022.9993550\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition (iWEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iWEM52897.2022.9993550","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本研究旨在开发一种方法来评估植入式医疗设备(植入式心脏起搏器/植入式心律转复除颤器)的电磁干扰(EMI)特性,相对于各种使用无线电波的设备,使用电磁场模拟。本文通过数值模拟研究了植入式医疗器械在近场和远场暴露条件下的电磁干扰特性与射频频率的关系。作为数值模型,制备了用于电磁干扰评估试验的植入式人体假体起搏器,并基于有限元法进行电磁场仿真,分析了4G和5G Sub6频段发射机附近的AIMD-EMI特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using FEM Simulation to Estimation of Active Implantable Medical Device EMI Characteristic in the 4G and 5G Sub-6 Frequency Bands
This study aims to develop a method to evaluate the electromagnetic interference (EMI) characteristics of implantable medical devices (implantable cardiac pacemakers/implantable cardioverter-defibrillators) with respect to various radio wave-using devices using electromagnetic field simulation. In this paper, the relationship between EMI characteristics of implantable medical devices and RF frequencies under near-field and far-field exposure conditions was investigated through numerical simulations. As a numerical model, an implantable pacemaker embedded in a human phantom used in the EMI evaluation test is prepared, and the AIMD-EMI characteristics near the transmitter in the 4G and 5G Sub6 frequency bands are analyzed by electromagnetic field simulation based on the finite element method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信