{"title":"谐波与潮流混合控制器在基于VSC的直流变电站中的应用","authors":"H. Chamorro, G. Ramos","doi":"10.1109/TDC-LA.2010.5762889","DOIUrl":null,"url":null,"abstract":"This document proposes the integration of different controller methodologies on a VSC (Voltage Source Converter) based HVDC (High Voltage Direct Current) stations and an active filter simultaneously. Hybrid control involves three different control techniques as follows: a discrete controller, which is in charge to regulate the voltage in the rectifier station, a fuzzy design manages the power flow in the inverter station toward the ac grid and a fuzzy controller is added to the active filter with the objective to reduce harmonic current in the VSC - HVDC stations. Simulation results validate the control performance in the whole system.","PeriodicalId":222318,"journal":{"name":"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Harmonic and power flow hybrid controller applied to VSC based HVDC stations\",\"authors\":\"H. Chamorro, G. Ramos\",\"doi\":\"10.1109/TDC-LA.2010.5762889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This document proposes the integration of different controller methodologies on a VSC (Voltage Source Converter) based HVDC (High Voltage Direct Current) stations and an active filter simultaneously. Hybrid control involves three different control techniques as follows: a discrete controller, which is in charge to regulate the voltage in the rectifier station, a fuzzy design manages the power flow in the inverter station toward the ac grid and a fuzzy controller is added to the active filter with the objective to reduce harmonic current in the VSC - HVDC stations. Simulation results validate the control performance in the whole system.\",\"PeriodicalId\":222318,\"journal\":{\"name\":\"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC-LA.2010.5762889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC-LA.2010.5762889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Harmonic and power flow hybrid controller applied to VSC based HVDC stations
This document proposes the integration of different controller methodologies on a VSC (Voltage Source Converter) based HVDC (High Voltage Direct Current) stations and an active filter simultaneously. Hybrid control involves three different control techniques as follows: a discrete controller, which is in charge to regulate the voltage in the rectifier station, a fuzzy design manages the power flow in the inverter station toward the ac grid and a fuzzy controller is added to the active filter with the objective to reduce harmonic current in the VSC - HVDC stations. Simulation results validate the control performance in the whole system.