{"title":"基于行波故障定位技术的交联聚乙烯电缆局部放电定位的可行性分析","authors":"Yongzhi Su, Yongduan Xue, Bingyin Xu, Liu Dong","doi":"10.1109/APAP.2011.6180642","DOIUrl":null,"url":null,"abstract":"This paper introduces the basis knowledge about partial discharge of XLPE cables, the idea that precise partial discharge location can be achieved by traveling waves fault location technology is proposed, then some key issues are discussed in this paper, that is the interference between consecutive partial discharges is analyzed, the measurability of partial discharges voltage is proved, and the effective signal acquisition for traveling waves of partial discharge is solved. Finally, the analyzed conclusions are verified by the simulation on partial discharge electrical model.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The feasibility analysis of partial discharge location of XLPE cables based on traveling waves fault location technology\",\"authors\":\"Yongzhi Su, Yongduan Xue, Bingyin Xu, Liu Dong\",\"doi\":\"10.1109/APAP.2011.6180642\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces the basis knowledge about partial discharge of XLPE cables, the idea that precise partial discharge location can be achieved by traveling waves fault location technology is proposed, then some key issues are discussed in this paper, that is the interference between consecutive partial discharges is analyzed, the measurability of partial discharges voltage is proved, and the effective signal acquisition for traveling waves of partial discharge is solved. Finally, the analyzed conclusions are verified by the simulation on partial discharge electrical model.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180642\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The feasibility analysis of partial discharge location of XLPE cables based on traveling waves fault location technology
This paper introduces the basis knowledge about partial discharge of XLPE cables, the idea that precise partial discharge location can be achieved by traveling waves fault location technology is proposed, then some key issues are discussed in this paper, that is the interference between consecutive partial discharges is analyzed, the measurability of partial discharges voltage is proved, and the effective signal acquisition for traveling waves of partial discharge is solved. Finally, the analyzed conclusions are verified by the simulation on partial discharge electrical model.