自动通气时的通气和肺力学监测。一个新设备。

B Jonson, L Nordström, S G Olsson, D Akerback
{"title":"自动通气时的通气和肺力学监测。一个新设备。","authors":"B Jonson,&nbsp;L Nordström,&nbsp;S G Olsson,&nbsp;D Akerback","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A device that allows continuous monitoring and recording of expired minute volume, tidal volume, resistance, compliance, indices of hyperinflation and other measures of ventilation and lung mechanics during automatic ventilation is described. After connection to the ventilator (Servoventilator 900) with one cable it is operating without any calibrations or other measures. The calculation of expired minute volume is done in a new way that eliminates errors due to compression of gas in the connecting lines. Calculations of compliance is made in a way allowing measurements even in patients with hyperinflation. Expiratory and inspiratory resistance values are obtained. The indices of hyperinflation in terms of measured flow and estimated alveolar pressure at the end of an expiration are discussed. The problems and benefits associated with measurements in much obstructive patients are analyzed. A short study of the performance of the calculator is presented.</p>","PeriodicalId":75638,"journal":{"name":"Bulletin de physio-pathologie respiratoire","volume":"11 5","pages":"729-43"},"PeriodicalIF":0.0000,"publicationDate":"1975-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring of ventilation and lung mechanics during automatic ventilation. A new device.\",\"authors\":\"B Jonson,&nbsp;L Nordström,&nbsp;S G Olsson,&nbsp;D Akerback\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A device that allows continuous monitoring and recording of expired minute volume, tidal volume, resistance, compliance, indices of hyperinflation and other measures of ventilation and lung mechanics during automatic ventilation is described. After connection to the ventilator (Servoventilator 900) with one cable it is operating without any calibrations or other measures. The calculation of expired minute volume is done in a new way that eliminates errors due to compression of gas in the connecting lines. Calculations of compliance is made in a way allowing measurements even in patients with hyperinflation. Expiratory and inspiratory resistance values are obtained. The indices of hyperinflation in terms of measured flow and estimated alveolar pressure at the end of an expiration are discussed. The problems and benefits associated with measurements in much obstructive patients are analyzed. A short study of the performance of the calculator is presented.</p>\",\"PeriodicalId\":75638,\"journal\":{\"name\":\"Bulletin de physio-pathologie respiratoire\",\"volume\":\"11 5\",\"pages\":\"729-43\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin de physio-pathologie respiratoire\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin de physio-pathologie respiratoire","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种可在自动通气过程中连续监测和记录过期分气量、潮气量、阻力、顺应性、恶性充气指数等通气和肺力学指标的装置。用一根电缆连接到呼吸机(servoventiator 900)后,无需任何校准或其他措施即可运行。失效分体积的计算采用了一种新的计算方法,消除了因管路气体压缩而产生的误差。即使在恶性通货膨胀患者中,依从性的计算方法也允许测量。获得呼气和吸气阻力值。根据测量的流量和估计的肺泡压力在呼气结束时的恶性膨胀指数进行了讨论。分析了许多阻塞性患者测量的问题和益处。本文对该计算器的性能作了简要的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Monitoring of ventilation and lung mechanics during automatic ventilation. A new device.

A device that allows continuous monitoring and recording of expired minute volume, tidal volume, resistance, compliance, indices of hyperinflation and other measures of ventilation and lung mechanics during automatic ventilation is described. After connection to the ventilator (Servoventilator 900) with one cable it is operating without any calibrations or other measures. The calculation of expired minute volume is done in a new way that eliminates errors due to compression of gas in the connecting lines. Calculations of compliance is made in a way allowing measurements even in patients with hyperinflation. Expiratory and inspiratory resistance values are obtained. The indices of hyperinflation in terms of measured flow and estimated alveolar pressure at the end of an expiration are discussed. The problems and benefits associated with measurements in much obstructive patients are analyzed. A short study of the performance of the calculator is presented.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信