{"title":"利用DPWM降低三电平混合ANPC逆变器开关损耗的开放容错方法","authors":"Ha-Rang Jo, Youngjong Ko, Kyo-Beum Lee","doi":"10.1109/CENCON51869.2021.9627299","DOIUrl":null,"url":null,"abstract":"This paper proposes an open fault tolerant control for reducing switching loss in a three-level Si/SiC hybrid active neutral-point clamped (HANPC) inverter. The Si/SiC hybrid ANPC inverter consists silicon (Si) switches and silicon-carbide (SiC) switches. The HANPC inverter is more economical compared to the full SiC ANPC inverter and the full SiC ANPC inverter provides the high efficiency and power density almost the same as the full-SiC ANPC inverter. The Si switches operate with the low switching frequency according to the fundamental frequency, and the SiC switches have the high switching frequency depend on the carrier-based switching methods. The HANPC inverter has two neutral-states which make the pole voltage zero. Even if one of the Si switches for generating the neutral-states has an open fault, therefore, the inverter can output the normal three-phase current with the tolerant control. When the open fault tolerant control is applied, however, the Si switches operate with the high switching frequency same as the SiC switches. As a result, the Si switches have the high switching loss and overheat. To solve this problem, the fault tolerant control using discontinuous pulse width modulation (DPWM) is proposed in this paper. The proposed method is verified through simulation results.","PeriodicalId":101715,"journal":{"name":"2021 IEEE Conference on Energy Conversion (CENCON)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Open Fault Tolerant Method Using DPWM for Reducing Switching Loss in Three-Level Hybrid ANPC Inverter\",\"authors\":\"Ha-Rang Jo, Youngjong Ko, Kyo-Beum Lee\",\"doi\":\"10.1109/CENCON51869.2021.9627299\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes an open fault tolerant control for reducing switching loss in a three-level Si/SiC hybrid active neutral-point clamped (HANPC) inverter. The Si/SiC hybrid ANPC inverter consists silicon (Si) switches and silicon-carbide (SiC) switches. The HANPC inverter is more economical compared to the full SiC ANPC inverter and the full SiC ANPC inverter provides the high efficiency and power density almost the same as the full-SiC ANPC inverter. The Si switches operate with the low switching frequency according to the fundamental frequency, and the SiC switches have the high switching frequency depend on the carrier-based switching methods. The HANPC inverter has two neutral-states which make the pole voltage zero. Even if one of the Si switches for generating the neutral-states has an open fault, therefore, the inverter can output the normal three-phase current with the tolerant control. When the open fault tolerant control is applied, however, the Si switches operate with the high switching frequency same as the SiC switches. As a result, the Si switches have the high switching loss and overheat. To solve this problem, the fault tolerant control using discontinuous pulse width modulation (DPWM) is proposed in this paper. The proposed method is verified through simulation results.\",\"PeriodicalId\":101715,\"journal\":{\"name\":\"2021 IEEE Conference on Energy Conversion (CENCON)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Conference on Energy Conversion (CENCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CENCON51869.2021.9627299\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Conference on Energy Conversion (CENCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CENCON51869.2021.9627299","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Open Fault Tolerant Method Using DPWM for Reducing Switching Loss in Three-Level Hybrid ANPC Inverter
This paper proposes an open fault tolerant control for reducing switching loss in a three-level Si/SiC hybrid active neutral-point clamped (HANPC) inverter. The Si/SiC hybrid ANPC inverter consists silicon (Si) switches and silicon-carbide (SiC) switches. The HANPC inverter is more economical compared to the full SiC ANPC inverter and the full SiC ANPC inverter provides the high efficiency and power density almost the same as the full-SiC ANPC inverter. The Si switches operate with the low switching frequency according to the fundamental frequency, and the SiC switches have the high switching frequency depend on the carrier-based switching methods. The HANPC inverter has two neutral-states which make the pole voltage zero. Even if one of the Si switches for generating the neutral-states has an open fault, therefore, the inverter can output the normal three-phase current with the tolerant control. When the open fault tolerant control is applied, however, the Si switches operate with the high switching frequency same as the SiC switches. As a result, the Si switches have the high switching loss and overheat. To solve this problem, the fault tolerant control using discontinuous pulse width modulation (DPWM) is proposed in this paper. The proposed method is verified through simulation results.