{"title":"新的六孔高精度反射系数公式","authors":"Wang Zhi, Sun Shenghe, Liu Yue","doi":"10.1109/CPEM.1988.671349","DOIUrl":null,"url":null,"abstract":"In this paper, a new formula to calculate load reflection coefficient is derived using absolute power theory of six-port measurement system. The computer simulation and experiment all show that in the presence of noise this formula is more precise than the one we used generally.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New Reflection Coefficient Formula With Higher Precision in Six-Port\",\"authors\":\"Wang Zhi, Sun Shenghe, Liu Yue\",\"doi\":\"10.1109/CPEM.1988.671349\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new formula to calculate load reflection coefficient is derived using absolute power theory of six-port measurement system. The computer simulation and experiment all show that in the presence of noise this formula is more precise than the one we used generally.\",\"PeriodicalId\":326579,\"journal\":{\"name\":\"1988 Conference on Precision Electromagnetic Measurements\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1988 Conference on Precision Electromagnetic Measurements\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.1988.671349\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1988 Conference on Precision Electromagnetic Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.1988.671349","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New Reflection Coefficient Formula With Higher Precision in Six-Port
In this paper, a new formula to calculate load reflection coefficient is derived using absolute power theory of six-port measurement system. The computer simulation and experiment all show that in the presence of noise this formula is more precise than the one we used generally.