{"title":"修改了不连续模式下的基本转换器","authors":"F. Himmelstoss, K. Edelmoser","doi":"10.1109/PEMC48073.2021.9432522","DOIUrl":null,"url":null,"abstract":"The basic converters (Buck, Boost, and Buck-Boost) are modified by a change of the position of the bulk capacitor. The capacitor is connected between the input and the output and not parallel to the output connectors. The three modified converter structures are analyzed by drawing the signal graphs, and the voltage transformation rate is derived. Simulation results are shown to verify the basic analyzes. The typical ringing in the discontinuous mode is than canceled with an additional circuit and simulation results show the effectiveness.","PeriodicalId":349940,"journal":{"name":"2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modified Basic Converters in the Discontinuous Mode\",\"authors\":\"F. Himmelstoss, K. Edelmoser\",\"doi\":\"10.1109/PEMC48073.2021.9432522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The basic converters (Buck, Boost, and Buck-Boost) are modified by a change of the position of the bulk capacitor. The capacitor is connected between the input and the output and not parallel to the output connectors. The three modified converter structures are analyzed by drawing the signal graphs, and the voltage transformation rate is derived. Simulation results are shown to verify the basic analyzes. The typical ringing in the discontinuous mode is than canceled with an additional circuit and simulation results show the effectiveness.\",\"PeriodicalId\":349940,\"journal\":{\"name\":\"2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEMC48073.2021.9432522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEMC48073.2021.9432522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modified Basic Converters in the Discontinuous Mode
The basic converters (Buck, Boost, and Buck-Boost) are modified by a change of the position of the bulk capacitor. The capacitor is connected between the input and the output and not parallel to the output connectors. The three modified converter structures are analyzed by drawing the signal graphs, and the voltage transformation rate is derived. Simulation results are shown to verify the basic analyzes. The typical ringing in the discontinuous mode is than canceled with an additional circuit and simulation results show the effectiveness.