{"title":"用多项式拟合技术计算133Xe间隙的肌肉血流量。","authors":"H Olkkonen, I M Penttilä","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A polynomial fitting technique suitable for small computers has been developed for calculation of the muscle blood flow function by the 133Xe clearance method. An application of the method for blood flow measurements in the lower limbs during hyperaemia is presented. The calculated maximum blood flow and peak time values were closely correlated with the manually elicited results.</p>","PeriodicalId":19324,"journal":{"name":"Nuclear-Medizin","volume":"14 4","pages":"390-4"},"PeriodicalIF":0.0000,"publicationDate":"1975-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computation of muscle blood flow by 133Xe clearance using polynomial fitting techniques.\",\"authors\":\"H Olkkonen, I M Penttilä\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A polynomial fitting technique suitable for small computers has been developed for calculation of the muscle blood flow function by the 133Xe clearance method. An application of the method for blood flow measurements in the lower limbs during hyperaemia is presented. The calculated maximum blood flow and peak time values were closely correlated with the manually elicited results.</p>\",\"PeriodicalId\":19324,\"journal\":{\"name\":\"Nuclear-Medizin\",\"volume\":\"14 4\",\"pages\":\"390-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear-Medizin\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear-Medizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Computation of muscle blood flow by 133Xe clearance using polynomial fitting techniques.
A polynomial fitting technique suitable for small computers has been developed for calculation of the muscle blood flow function by the 133Xe clearance method. An application of the method for blood flow measurements in the lower limbs during hyperaemia is presented. The calculated maximum blood flow and peak time values were closely correlated with the manually elicited results.