{"title":"同步发电机,励磁和调速器建模在ATP-EMTP互连DG的研究","authors":"F. Moura, J. Camacho, J. W. Resende, W. Mendes","doi":"10.1109/ICELMACH.2008.4800246","DOIUrl":null,"url":null,"abstract":"The main task in this paper is to present a performance analysis of a distribution network in the presence of a synchronous generator with its speed and voltage regulators, in parallel with the distribution system, for distributed generation studies. Must be highlighted that this generator is driven by a steam turbine, and the whole system with regulators and the equivalent of the power authority system in the point of connection (PAC) are modeled in the ldquoATP - Alternative Transients Programrdquo. Technical questions studied here refer to steady-state voltage profile, voltage stability, voltage dip due to a balanced three-phase fault, load rejection, distribution line outage and the behavior of machine regulators facing the aforementioned contingencies. Results show that, in some cases, the independent power producer (IPA) can be a menace to the physical integrity of the system and in other cases can be very beneficial to the distribution system in the point of connection.","PeriodicalId":416125,"journal":{"name":"2008 18th International Conference on Electrical Machines","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Synchronous generator, excitation and speed governor modeling in ATP-EMTP for interconnected DG Studies\",\"authors\":\"F. Moura, J. Camacho, J. W. Resende, W. Mendes\",\"doi\":\"10.1109/ICELMACH.2008.4800246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main task in this paper is to present a performance analysis of a distribution network in the presence of a synchronous generator with its speed and voltage regulators, in parallel with the distribution system, for distributed generation studies. Must be highlighted that this generator is driven by a steam turbine, and the whole system with regulators and the equivalent of the power authority system in the point of connection (PAC) are modeled in the ldquoATP - Alternative Transients Programrdquo. Technical questions studied here refer to steady-state voltage profile, voltage stability, voltage dip due to a balanced three-phase fault, load rejection, distribution line outage and the behavior of machine regulators facing the aforementioned contingencies. Results show that, in some cases, the independent power producer (IPA) can be a menace to the physical integrity of the system and in other cases can be very beneficial to the distribution system in the point of connection.\",\"PeriodicalId\":416125,\"journal\":{\"name\":\"2008 18th International Conference on Electrical Machines\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 18th International Conference on Electrical Machines\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2008.4800246\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 18th International Conference on Electrical Machines","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2008.4800246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Synchronous generator, excitation and speed governor modeling in ATP-EMTP for interconnected DG Studies
The main task in this paper is to present a performance analysis of a distribution network in the presence of a synchronous generator with its speed and voltage regulators, in parallel with the distribution system, for distributed generation studies. Must be highlighted that this generator is driven by a steam turbine, and the whole system with regulators and the equivalent of the power authority system in the point of connection (PAC) are modeled in the ldquoATP - Alternative Transients Programrdquo. Technical questions studied here refer to steady-state voltage profile, voltage stability, voltage dip due to a balanced three-phase fault, load rejection, distribution line outage and the behavior of machine regulators facing the aforementioned contingencies. Results show that, in some cases, the independent power producer (IPA) can be a menace to the physical integrity of the system and in other cases can be very beneficial to the distribution system in the point of connection.