肺病人异步远程超声监测采集系统的研制

Esteban Avilés, Carlos Zegarra, Francis Reyes, Bejamin Castaneda, Stefano Enrique Romero
{"title":"肺病人异步远程超声监测采集系统的研制","authors":"Esteban Avilés, Carlos Zegarra, Francis Reyes, Bejamin Castaneda, Stefano Enrique Romero","doi":"10.1117/12.2670097","DOIUrl":null,"url":null,"abstract":"Lung ultrasound imaging allows the detection and evaluation of the lung damage generated by COVID-19. However, several infrastructure and logistical limitations prevent them from being carried out in isolated and remote areas. In this work, a system for the acquisition of medical images through asynchronous tele-ultrasounds was developed. The system is based on a graphical user interface, which records the three video cameras, the ultrasound image and the accelerometer simultaneously. The interface was developed according to the Volume Sweep Imaging acquisition protocol. The translational and rotational movement of the transducer are tracked and monitored by the accelerometer and the position of the transducer is obtained from the images acquired by the three video cameras. The results show a correct functioning of the system overall, being viable to be implemented for data acquisition and calculation of error, although in order to validate the error calculation there is still more research to be done.","PeriodicalId":147201,"journal":{"name":"Symposium on Medical Information Processing and Analysis","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an acquisition system to monitoring asynchronous tele-ultrasound for lung patients\",\"authors\":\"Esteban Avilés, Carlos Zegarra, Francis Reyes, Bejamin Castaneda, Stefano Enrique Romero\",\"doi\":\"10.1117/12.2670097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lung ultrasound imaging allows the detection and evaluation of the lung damage generated by COVID-19. However, several infrastructure and logistical limitations prevent them from being carried out in isolated and remote areas. In this work, a system for the acquisition of medical images through asynchronous tele-ultrasounds was developed. The system is based on a graphical user interface, which records the three video cameras, the ultrasound image and the accelerometer simultaneously. The interface was developed according to the Volume Sweep Imaging acquisition protocol. The translational and rotational movement of the transducer are tracked and monitored by the accelerometer and the position of the transducer is obtained from the images acquired by the three video cameras. The results show a correct functioning of the system overall, being viable to be implemented for data acquisition and calculation of error, although in order to validate the error calculation there is still more research to be done.\",\"PeriodicalId\":147201,\"journal\":{\"name\":\"Symposium on Medical Information Processing and Analysis\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Symposium on Medical Information Processing and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2670097\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Symposium on Medical Information Processing and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2670097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

肺部超声成像可以检测和评估COVID-19引起的肺部损伤。然而,一些基础设施和后勤方面的限制使它们无法在孤立和偏远地区进行。本文研制了一种异步远程超声医学图像采集系统。该系统基于图形用户界面,同时记录三个摄像机、超声图像和加速度计。该接口是根据体扫描成像采集协议开发的。加速度计跟踪和监测换能器的平移和旋转运动,并根据三个摄像机采集的图像获得换能器的位置。结果表明,该系统总体上运行正常,在数据采集和误差计算方面是可行的,但为了验证误差计算还有更多的研究要做。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of an acquisition system to monitoring asynchronous tele-ultrasound for lung patients
Lung ultrasound imaging allows the detection and evaluation of the lung damage generated by COVID-19. However, several infrastructure and logistical limitations prevent them from being carried out in isolated and remote areas. In this work, a system for the acquisition of medical images through asynchronous tele-ultrasounds was developed. The system is based on a graphical user interface, which records the three video cameras, the ultrasound image and the accelerometer simultaneously. The interface was developed according to the Volume Sweep Imaging acquisition protocol. The translational and rotational movement of the transducer are tracked and monitored by the accelerometer and the position of the transducer is obtained from the images acquired by the three video cameras. The results show a correct functioning of the system overall, being viable to be implemented for data acquisition and calculation of error, although in order to validate the error calculation there is still more research to be done.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信