Esteban Avilés, Carlos Zegarra, Francis Reyes, Bejamin Castaneda, Stefano Enrique Romero
{"title":"肺病人异步远程超声监测采集系统的研制","authors":"Esteban Avilés, Carlos Zegarra, Francis Reyes, Bejamin Castaneda, Stefano Enrique Romero","doi":"10.1117/12.2670097","DOIUrl":null,"url":null,"abstract":"Lung ultrasound imaging allows the detection and evaluation of the lung damage generated by COVID-19. However, several infrastructure and logistical limitations prevent them from being carried out in isolated and remote areas. In this work, a system for the acquisition of medical images through asynchronous tele-ultrasounds was developed. The system is based on a graphical user interface, which records the three video cameras, the ultrasound image and the accelerometer simultaneously. The interface was developed according to the Volume Sweep Imaging acquisition protocol. The translational and rotational movement of the transducer are tracked and monitored by the accelerometer and the position of the transducer is obtained from the images acquired by the three video cameras. The results show a correct functioning of the system overall, being viable to be implemented for data acquisition and calculation of error, although in order to validate the error calculation there is still more research to be done.","PeriodicalId":147201,"journal":{"name":"Symposium on Medical Information Processing and Analysis","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an acquisition system to monitoring asynchronous tele-ultrasound for lung patients\",\"authors\":\"Esteban Avilés, Carlos Zegarra, Francis Reyes, Bejamin Castaneda, Stefano Enrique Romero\",\"doi\":\"10.1117/12.2670097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lung ultrasound imaging allows the detection and evaluation of the lung damage generated by COVID-19. However, several infrastructure and logistical limitations prevent them from being carried out in isolated and remote areas. In this work, a system for the acquisition of medical images through asynchronous tele-ultrasounds was developed. The system is based on a graphical user interface, which records the three video cameras, the ultrasound image and the accelerometer simultaneously. The interface was developed according to the Volume Sweep Imaging acquisition protocol. The translational and rotational movement of the transducer are tracked and monitored by the accelerometer and the position of the transducer is obtained from the images acquired by the three video cameras. The results show a correct functioning of the system overall, being viable to be implemented for data acquisition and calculation of error, although in order to validate the error calculation there is still more research to be done.\",\"PeriodicalId\":147201,\"journal\":{\"name\":\"Symposium on Medical Information Processing and Analysis\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Symposium on Medical Information Processing and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2670097\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Symposium on Medical Information Processing and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2670097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of an acquisition system to monitoring asynchronous tele-ultrasound for lung patients
Lung ultrasound imaging allows the detection and evaluation of the lung damage generated by COVID-19. However, several infrastructure and logistical limitations prevent them from being carried out in isolated and remote areas. In this work, a system for the acquisition of medical images through asynchronous tele-ultrasounds was developed. The system is based on a graphical user interface, which records the three video cameras, the ultrasound image and the accelerometer simultaneously. The interface was developed according to the Volume Sweep Imaging acquisition protocol. The translational and rotational movement of the transducer are tracked and monitored by the accelerometer and the position of the transducer is obtained from the images acquired by the three video cameras. The results show a correct functioning of the system overall, being viable to be implemented for data acquisition and calculation of error, although in order to validate the error calculation there is still more research to be done.