O. Kherif, T. Zebbadji, S. Chiheb, Y. Benmahamed, M. Teguar
{"title":"21电平非对称多电平逆变器的性能研究","authors":"O. Kherif, T. Zebbadji, S. Chiheb, Y. Benmahamed, M. Teguar","doi":"10.1109/ICAEE53772.2022.9962034","DOIUrl":null,"url":null,"abstract":"This paper deals with a 21-level asymmetrical voltage inverter with a reduced number of switching components and isolated DC sources. A brief description of the used multilevel inverter is provided, including the circuit configuration and control signals. A pre-calculated switching technique is implemented where the inverter performance is achieved throughout a parametric analysis (THD and fundamental component amplitude). Therewith, selected simulation results are shown to discuss the output voltage and current for different RL-loads and modulation index. The computed current and load voltage signals show a reduced THD that is varying in the permissible limits.","PeriodicalId":206584,"journal":{"name":"2022 2nd International Conference on Advanced Electrical Engineering (ICAEE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"On the Performance of A 21-level Asymmetrical Multilevel Voltage Inverter\",\"authors\":\"O. Kherif, T. Zebbadji, S. Chiheb, Y. Benmahamed, M. Teguar\",\"doi\":\"10.1109/ICAEE53772.2022.9962034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with a 21-level asymmetrical voltage inverter with a reduced number of switching components and isolated DC sources. A brief description of the used multilevel inverter is provided, including the circuit configuration and control signals. A pre-calculated switching technique is implemented where the inverter performance is achieved throughout a parametric analysis (THD and fundamental component amplitude). Therewith, selected simulation results are shown to discuss the output voltage and current for different RL-loads and modulation index. The computed current and load voltage signals show a reduced THD that is varying in the permissible limits.\",\"PeriodicalId\":206584,\"journal\":{\"name\":\"2022 2nd International Conference on Advanced Electrical Engineering (ICAEE)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 2nd International Conference on Advanced Electrical Engineering (ICAEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAEE53772.2022.9962034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd International Conference on Advanced Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE53772.2022.9962034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On the Performance of A 21-level Asymmetrical Multilevel Voltage Inverter
This paper deals with a 21-level asymmetrical voltage inverter with a reduced number of switching components and isolated DC sources. A brief description of the used multilevel inverter is provided, including the circuit configuration and control signals. A pre-calculated switching technique is implemented where the inverter performance is achieved throughout a parametric analysis (THD and fundamental component amplitude). Therewith, selected simulation results are shown to discuss the output voltage and current for different RL-loads and modulation index. The computed current and load voltage signals show a reduced THD that is varying in the permissible limits.