{"title":"状态估计最优传感器部署中测量不确定度的考虑","authors":"S. Chakrabarti, Demetrios G. Eliades, E. Kyriakides, M. Albu","doi":"10.1109/WISP.2007.4447605","DOIUrl":null,"url":null,"abstract":"This paper proposes a method for optimal placement of phasor measurement units (PMUs) for measuring the states of a power system. A method to compute the measurement uncertainty associated with the estimated states is also illustrated in the paper. The PMU placement strategy ensures complete observability of the power system states for normal operating conditions, as well as under the loss of a single transmission line or even a single measurement unit. An integer quadratic programming approach is used to minimize the total number of PMUs required to make the system completely observable, and to maximize the measurement redundancy at the power system busses. The goal of the research is to take into account the measurement uncertainty while determining the optimal number and locations of the PMUs for state estimation. Simulation results on the IEEE 14-bus test system are presented in this paper.","PeriodicalId":164902,"journal":{"name":"2007 IEEE International Symposium on Intelligent Signal Processing","volume":"269 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":"{\"title\":\"Measurement Uncertainty Considerations in Optimal Sensor Deployment for State Estimation\",\"authors\":\"S. Chakrabarti, Demetrios G. Eliades, E. Kyriakides, M. Albu\",\"doi\":\"10.1109/WISP.2007.4447605\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a method for optimal placement of phasor measurement units (PMUs) for measuring the states of a power system. A method to compute the measurement uncertainty associated with the estimated states is also illustrated in the paper. The PMU placement strategy ensures complete observability of the power system states for normal operating conditions, as well as under the loss of a single transmission line or even a single measurement unit. An integer quadratic programming approach is used to minimize the total number of PMUs required to make the system completely observable, and to maximize the measurement redundancy at the power system busses. The goal of the research is to take into account the measurement uncertainty while determining the optimal number and locations of the PMUs for state estimation. Simulation results on the IEEE 14-bus test system are presented in this paper.\",\"PeriodicalId\":164902,\"journal\":{\"name\":\"2007 IEEE International Symposium on Intelligent Signal Processing\",\"volume\":\"269 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE International Symposium on Intelligent Signal Processing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WISP.2007.4447605\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Symposium on Intelligent Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WISP.2007.4447605","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

摘要

本文提出了一种用于测量电力系统状态的相量测量单元(pmu)的优化配置方法。本文还介绍了一种计算与估计状态相关的测量不确定度的方法。PMU放置策略确保在正常运行条件下,以及在单个传输线甚至单个测量单元损耗下,电力系统状态的完全可观察性。整数二次规划方法用于最小化pmu的总数,使系统完全可观察,并最大化测量冗余在电力系统母线。研究的目的是在确定pmu的最佳数量和位置进行状态估计时考虑测量不确定度。本文给出了在IEEE 14总线测试系统上的仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement Uncertainty Considerations in Optimal Sensor Deployment for State Estimation
This paper proposes a method for optimal placement of phasor measurement units (PMUs) for measuring the states of a power system. A method to compute the measurement uncertainty associated with the estimated states is also illustrated in the paper. The PMU placement strategy ensures complete observability of the power system states for normal operating conditions, as well as under the loss of a single transmission line or even a single measurement unit. An integer quadratic programming approach is used to minimize the total number of PMUs required to make the system completely observable, and to maximize the measurement redundancy at the power system busses. The goal of the research is to take into account the measurement uncertainty while determining the optimal number and locations of the PMUs for state estimation. Simulation results on the IEEE 14-bus test system are presented in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信