基于SOGI-SF滤波器的三相并网太阳能转换系统

P. Chakraborty, Tripurari Nath Gupta, Nitesh Kumar
{"title":"基于SOGI-SF滤波器的三相并网太阳能转换系统","authors":"P. Chakraborty, Tripurari Nath Gupta, Nitesh Kumar","doi":"10.1109/CONIT59222.2023.10205746","DOIUrl":null,"url":null,"abstract":"Under unusual grid conditions, in order to improve the power quality of the system, a three-phase micro-grid based on a Second Order Generalized Integrator-Sequence Filter (SOGI-SF) is developed in this work. The solar PV generating system basically meets the energy requirements at the distribution end. When energy is being transferred from the source to the load, there are many problems encountered during the process. The main objective is to maintain a high power factor at the grid. This can be achieved by providing the reactive power needed by the load. The non-linear demand is primarily responsible for introducing harmonics into the system. For resolving power quality problems brought on by nonlinear loads, the SOGI-SF control that is being demonstrated is very effective. The performance of the system is evaluated under dynamic irradiance. The THD of the grid current is maintained as per the IEEE 519-2018 standard.","PeriodicalId":377623,"journal":{"name":"2023 3rd International Conference on Intelligent Technologies (CONIT)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SOGI-SF Filter based Three Phase Grid Tied Solar Energy Conversion System\",\"authors\":\"P. Chakraborty, Tripurari Nath Gupta, Nitesh Kumar\",\"doi\":\"10.1109/CONIT59222.2023.10205746\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Under unusual grid conditions, in order to improve the power quality of the system, a three-phase micro-grid based on a Second Order Generalized Integrator-Sequence Filter (SOGI-SF) is developed in this work. The solar PV generating system basically meets the energy requirements at the distribution end. When energy is being transferred from the source to the load, there are many problems encountered during the process. The main objective is to maintain a high power factor at the grid. This can be achieved by providing the reactive power needed by the load. The non-linear demand is primarily responsible for introducing harmonics into the system. For resolving power quality problems brought on by nonlinear loads, the SOGI-SF control that is being demonstrated is very effective. The performance of the system is evaluated under dynamic irradiance. The THD of the grid current is maintained as per the IEEE 519-2018 standard.\",\"PeriodicalId\":377623,\"journal\":{\"name\":\"2023 3rd International Conference on Intelligent Technologies (CONIT)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 3rd International Conference on Intelligent Technologies (CONIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CONIT59222.2023.10205746\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 3rd International Conference on Intelligent Technologies (CONIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CONIT59222.2023.10205746","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在异常电网条件下,为了改善系统的电能质量,本文提出了一种基于二阶广义积分器序列滤波器(SOGI-SF)的三相微电网。太阳能光伏发电系统基本满足配电端的能源需求。当能量从源向负载传递时,在此过程中会遇到许多问题。主要目标是在电网中保持高功率因数。这可以通过提供负载所需的无功功率来实现。非线性需求主要负责将谐波引入系统。对于解决非线性负载带来的电能质量问题,所演示的SOGI-SF控制是非常有效的。在动态辐照下对系统的性能进行了评价。电网电流的THD按照IEEE 519-2018标准进行维护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SOGI-SF Filter based Three Phase Grid Tied Solar Energy Conversion System
Under unusual grid conditions, in order to improve the power quality of the system, a three-phase micro-grid based on a Second Order Generalized Integrator-Sequence Filter (SOGI-SF) is developed in this work. The solar PV generating system basically meets the energy requirements at the distribution end. When energy is being transferred from the source to the load, there are many problems encountered during the process. The main objective is to maintain a high power factor at the grid. This can be achieved by providing the reactive power needed by the load. The non-linear demand is primarily responsible for introducing harmonics into the system. For resolving power quality problems brought on by nonlinear loads, the SOGI-SF control that is being demonstrated is very effective. The performance of the system is evaluated under dynamic irradiance. The THD of the grid current is maintained as per the IEEE 519-2018 standard.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信