{"title":"过零电流区的死区补偿","authors":"A.C. Oliveira, C. Jacobina, Antonio M. N. Lima, E. D. da Silva","doi":"10.1109/PESC.2003.1217749","DOIUrl":null,"url":null,"abstract":"The compensation of the effects of the dead-time based on the modification of the pulse-width of the command signals requires the knowledge of the polarity of the current flowing through the power switch. This polarity defines if the pulse-width must be widened or shortened. In the zero-crossing current region it is difficult to determine the current polarity and thus the compensation may be incorrect and consequently the output inverter voltage can be distorted. This article discusses such polarity based compensation technique and proposes a solution to minimize the inverter voltage distortion in the zero-crossing current region. In the proposed solution, the polarity of the current together with its instantaneous value are employed to correct the pulse-width. The proposed solution has been tested experimentally and the results obtained were considered satisfactory when compared to the standard technique where the compensating term is kept fix no matter what are the polarity and the magnitude of the current flowing through the power switch.","PeriodicalId":236199,"journal":{"name":"IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Dead-time compensation in the zero-crossing current region\",\"authors\":\"A.C. Oliveira, C. Jacobina, Antonio M. N. Lima, E. D. da Silva\",\"doi\":\"10.1109/PESC.2003.1217749\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The compensation of the effects of the dead-time based on the modification of the pulse-width of the command signals requires the knowledge of the polarity of the current flowing through the power switch. This polarity defines if the pulse-width must be widened or shortened. In the zero-crossing current region it is difficult to determine the current polarity and thus the compensation may be incorrect and consequently the output inverter voltage can be distorted. This article discusses such polarity based compensation technique and proposes a solution to minimize the inverter voltage distortion in the zero-crossing current region. In the proposed solution, the polarity of the current together with its instantaneous value are employed to correct the pulse-width. The proposed solution has been tested experimentally and the results obtained were considered satisfactory when compared to the standard technique where the compensating term is kept fix no matter what are the polarity and the magnitude of the current flowing through the power switch.\",\"PeriodicalId\":236199,\"journal\":{\"name\":\"IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.2003.1217749\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.2003.1217749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

通过修改命令信号的脉宽来补偿死区时间的影响,需要了解流经电源开关的电流的极性。这个极性决定了脉冲宽度是否必须加宽或缩短。在过零电流区很难确定电流极性,因此补偿可能不正确,从而导致逆变器输出电压失真。本文讨论了这种基于极性的补偿技术,并提出了一种最小化过零电流区域逆变器电压畸变的解决方案。在该解决方案中,采用电流的极性及其瞬时值来校正脉宽。该方法经实验验证,与标准方法相比,补偿项无论电流的极性和大小如何都是固定的,得到的结果令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dead-time compensation in the zero-crossing current region
The compensation of the effects of the dead-time based on the modification of the pulse-width of the command signals requires the knowledge of the polarity of the current flowing through the power switch. This polarity defines if the pulse-width must be widened or shortened. In the zero-crossing current region it is difficult to determine the current polarity and thus the compensation may be incorrect and consequently the output inverter voltage can be distorted. This article discusses such polarity based compensation technique and proposes a solution to minimize the inverter voltage distortion in the zero-crossing current region. In the proposed solution, the polarity of the current together with its instantaneous value are employed to correct the pulse-width. The proposed solution has been tested experimentally and the results obtained were considered satisfactory when compared to the standard technique where the compensating term is kept fix no matter what are the polarity and the magnitude of the current flowing through the power switch.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信