考虑谐波谐振的子输电网电容优化配置

M. Nasiri, Behdad Faridpak, M. Farrokhifar, Arman Alahyari
{"title":"考虑谐波谐振的子输电网电容优化配置","authors":"M. Nasiri, Behdad Faridpak, M. Farrokhifar, Arman Alahyari","doi":"10.1109/REEPE49198.2020.9059142","DOIUrl":null,"url":null,"abstract":"In conventional electricity grids, although power plants can support the active power of loads, transmission and sub-transmission networks deal with overloading situations in the transformers caused by reactive power of loads. Hence, local reactive power compensation of loads by capacitor allocation is an important solution. In this paper, the genetic algorithm (GA) is employed for the optimal capacitor allocation then the transformer tap changing is used to regulate the voltage profile in the buses. The tap regulation can eliminate the over-voltage, which is produced by capacitors installation. Eventually, harmonic analysis is applied to prevent harmonic resonance in capacitor banks. For validating the efficiency of the proposed method, it is examined in the typical transmission and subtransmission networks. The simulations are done in DIgSILENT software using DIgSILENT Programming Language (DPL) that is interfaced with MATLAB software.","PeriodicalId":142369,"journal":{"name":"2020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Optimal Capacitor Allocation in Sub-Transmission Networks to Mitigate Overloading Considering Harmonic Resonance\",\"authors\":\"M. Nasiri, Behdad Faridpak, M. Farrokhifar, Arman Alahyari\",\"doi\":\"10.1109/REEPE49198.2020.9059142\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In conventional electricity grids, although power plants can support the active power of loads, transmission and sub-transmission networks deal with overloading situations in the transformers caused by reactive power of loads. Hence, local reactive power compensation of loads by capacitor allocation is an important solution. In this paper, the genetic algorithm (GA) is employed for the optimal capacitor allocation then the transformer tap changing is used to regulate the voltage profile in the buses. The tap regulation can eliminate the over-voltage, which is produced by capacitors installation. Eventually, harmonic analysis is applied to prevent harmonic resonance in capacitor banks. For validating the efficiency of the proposed method, it is examined in the typical transmission and subtransmission networks. The simulations are done in DIgSILENT software using DIgSILENT Programming Language (DPL) that is interfaced with MATLAB software.\",\"PeriodicalId\":142369,\"journal\":{\"name\":\"2020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REEPE49198.2020.9059142\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REEPE49198.2020.9059142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在常规电网中,虽然发电厂可以支持负载的有功功率,但输电和分输电网络要处理负载的无功功率引起的变压器过载情况。因此,通过电容器配置对负载进行局部无功补偿是解决这一问题的重要方法。本文采用遗传算法对电容器进行优化配置,并利用变压器分接变化对母线电压分布进行调节。抽头调节可以消除电容器安装产生的过电压。最后,应用谐波分析来防止电容器组中的谐波谐振。为了验证该方法的有效性,在典型的传输和子传输网络中进行了测试。仿真是在DIgSILENT软件中使用DIgSILENT编程语言(DPL)与MATLAB软件接口进行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal Capacitor Allocation in Sub-Transmission Networks to Mitigate Overloading Considering Harmonic Resonance
In conventional electricity grids, although power plants can support the active power of loads, transmission and sub-transmission networks deal with overloading situations in the transformers caused by reactive power of loads. Hence, local reactive power compensation of loads by capacitor allocation is an important solution. In this paper, the genetic algorithm (GA) is employed for the optimal capacitor allocation then the transformer tap changing is used to regulate the voltage profile in the buses. The tap regulation can eliminate the over-voltage, which is produced by capacitors installation. Eventually, harmonic analysis is applied to prevent harmonic resonance in capacitor banks. For validating the efficiency of the proposed method, it is examined in the typical transmission and subtransmission networks. The simulations are done in DIgSILENT software using DIgSILENT Programming Language (DPL) that is interfaced with MATLAB software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信