机器人血管介入程序主设备可用性测试*

Hwa-Seob Song, Jaehong Woo, J. Won, B. Yi
{"title":"机器人血管介入程序主设备可用性测试*","authors":"Hwa-Seob Song, Jaehong Woo, J. Won, B. Yi","doi":"10.1109/RO-MAN47096.2020.9223513","DOIUrl":null,"url":null,"abstract":"Conventional vascular intervention radiology (VIR) procedure presents a few challenges to overcome, which are radiation exposure issue during the procedure under X-ray, physical and mental burdens to the operator in handling catheter and guidewire. We propose a robotic approach to resolve such problems. Specifically, this paper deals with usability test of master devices to control four degrees of freedom (4-DOF) robotic vascular intervention system. The usability of two master devices was measured in terms of task completion time and NASA-TLX index. Both novice and expert group participated in master-slave vascular intervention procedure based on abdominal blood vessel phantom. We found that position to velocity based master device is much effective compared to position to position based master device.","PeriodicalId":383722,"journal":{"name":"2020 29th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Usability Test of Master Devices for Robotic Vascular Intervention Procedure*\",\"authors\":\"Hwa-Seob Song, Jaehong Woo, J. Won, B. Yi\",\"doi\":\"10.1109/RO-MAN47096.2020.9223513\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conventional vascular intervention radiology (VIR) procedure presents a few challenges to overcome, which are radiation exposure issue during the procedure under X-ray, physical and mental burdens to the operator in handling catheter and guidewire. We propose a robotic approach to resolve such problems. Specifically, this paper deals with usability test of master devices to control four degrees of freedom (4-DOF) robotic vascular intervention system. The usability of two master devices was measured in terms of task completion time and NASA-TLX index. Both novice and expert group participated in master-slave vascular intervention procedure based on abdominal blood vessel phantom. We found that position to velocity based master device is much effective compared to position to position based master device.\",\"PeriodicalId\":383722,\"journal\":{\"name\":\"2020 29th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 29th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RO-MAN47096.2020.9223513\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 29th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RO-MAN47096.2020.9223513","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

常规血管介入放射(VIR)手术存在一些需要克服的挑战,其中包括x射线照射过程中的辐射暴露问题,以及操作导管和导丝时操作者的身体和精神负担。我们提出一种机器人方法来解决这些问题。具体来说,本文研究了控制四自由度机器人血管介入系统的主装置的可用性测试。用任务完成时间和NASA-TLX指数来衡量两个主设备的可用性。新手组和专家组均参与了基于腹腔血管幻像的主从血管干预程序。我们发现基于位置到速度的主装置比基于位置到位置的主装置更有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Usability Test of Master Devices for Robotic Vascular Intervention Procedure*
Conventional vascular intervention radiology (VIR) procedure presents a few challenges to overcome, which are radiation exposure issue during the procedure under X-ray, physical and mental burdens to the operator in handling catheter and guidewire. We propose a robotic approach to resolve such problems. Specifically, this paper deals with usability test of master devices to control four degrees of freedom (4-DOF) robotic vascular intervention system. The usability of two master devices was measured in terms of task completion time and NASA-TLX index. Both novice and expert group participated in master-slave vascular intervention procedure based on abdominal blood vessel phantom. We found that position to velocity based master device is much effective compared to position to position based master device.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信