Sruthi Mavila Pathayapurayil, Rupesh Kumari, T. Chelliah
{"title":"传感器网络攻击对并网变频水电站的影响分析","authors":"Sruthi Mavila Pathayapurayil, Rupesh Kumari, T. Chelliah","doi":"10.1109/IAS54023.2022.9940043","DOIUrl":null,"url":null,"abstract":"The variable speed doubly fed induction generators (DFIGs) are the future of hydrogenating plants owing to their flexible nature and speedy response. The new digitalized power scenario needs attention on cyber-attacks and measures suggested as per IEC Standard 62433 (2019): Security for Industrial Automation and Control Systems. Different system responds differently to cyber-attacks. This work focus on the impact analysis of speed and DC link voltage sensor attacks on grid connected large hydrogenating unit, of capacity 250MW. MATLAB simulations are carried out for False Data Injection (FDI) and Denial of Service (DoS) attacks and analyze the system behavior. The simulation results demonstrate that the system is affected severely under different attack scenarios.","PeriodicalId":193587,"journal":{"name":"2022 IEEE Industry Applications Society Annual Meeting (IAS)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Impact Analysis of Sensor Cyber-Attacks on Grid-Tied Variable Speed Hydropower Plants\",\"authors\":\"Sruthi Mavila Pathayapurayil, Rupesh Kumari, T. Chelliah\",\"doi\":\"10.1109/IAS54023.2022.9940043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The variable speed doubly fed induction generators (DFIGs) are the future of hydrogenating plants owing to their flexible nature and speedy response. The new digitalized power scenario needs attention on cyber-attacks and measures suggested as per IEC Standard 62433 (2019): Security for Industrial Automation and Control Systems. Different system responds differently to cyber-attacks. This work focus on the impact analysis of speed and DC link voltage sensor attacks on grid connected large hydrogenating unit, of capacity 250MW. MATLAB simulations are carried out for False Data Injection (FDI) and Denial of Service (DoS) attacks and analyze the system behavior. The simulation results demonstrate that the system is affected severely under different attack scenarios.\",\"PeriodicalId\":193587,\"journal\":{\"name\":\"2022 IEEE Industry Applications Society Annual Meeting (IAS)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Industry Applications Society Annual Meeting (IAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS54023.2022.9940043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Industry Applications Society Annual Meeting (IAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS54023.2022.9940043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impact Analysis of Sensor Cyber-Attacks on Grid-Tied Variable Speed Hydropower Plants
The variable speed doubly fed induction generators (DFIGs) are the future of hydrogenating plants owing to their flexible nature and speedy response. The new digitalized power scenario needs attention on cyber-attacks and measures suggested as per IEC Standard 62433 (2019): Security for Industrial Automation and Control Systems. Different system responds differently to cyber-attacks. This work focus on the impact analysis of speed and DC link voltage sensor attacks on grid connected large hydrogenating unit, of capacity 250MW. MATLAB simulations are carried out for False Data Injection (FDI) and Denial of Service (DoS) attacks and analyze the system behavior. The simulation results demonstrate that the system is affected severely under different attack scenarios.