与有源滤波器有关的配电设备中压负荷特性

F. Corasaniti, M. B. Barbieri, P. L. Arnera, M. Valla
{"title":"与有源滤波器有关的配电设备中压负荷特性","authors":"F. Corasaniti, M. B. Barbieri, P. L. Arnera, M. Valla","doi":"10.1109/TDCLA.2006.311418","DOIUrl":null,"url":null,"abstract":"The behavior of the actual load of an electric energy distribution utility by means of voltage and current measurements is analyzed in this paper. Steady and transient states are taken into account. The main attention is fixed in points where present shunt compensation is installed. Results of field measurements and the connection and disconnection of capacitor banks are shown. Studies for future compensation are detailed and the possible advantages of active filter incorporation are analyzed in order to replace or complement the existing compensation. The minimal requirements are established in order to consider the design of the active filters and their compatibility with the existing installations","PeriodicalId":406067,"journal":{"name":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Load Characterization in Medium Voltage of an Electric Distribution Utility Related to Active Filters\",\"authors\":\"F. Corasaniti, M. B. Barbieri, P. L. Arnera, M. Valla\",\"doi\":\"10.1109/TDCLA.2006.311418\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The behavior of the actual load of an electric energy distribution utility by means of voltage and current measurements is analyzed in this paper. Steady and transient states are taken into account. The main attention is fixed in points where present shunt compensation is installed. Results of field measurements and the connection and disconnection of capacitor banks are shown. Studies for future compensation are detailed and the possible advantages of active filter incorporation are analyzed in order to replace or complement the existing compensation. The minimal requirements are established in order to consider the design of the active filters and their compatibility with the existing installations\",\"PeriodicalId\":406067,\"journal\":{\"name\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDCLA.2006.311418\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLA.2006.311418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文通过电压和电流的测量,分析了某配电网实际负荷的特性。考虑了稳态和瞬态。主要注意的是安装了当前分流补偿的点。给出了现场测量和电容器组连接和断开的结果。对未来的补偿进行了详细的研究,并分析了加入有源滤波器的可能优势,以取代或补充现有的补偿。为了考虑有源滤波器的设计及其与现有装置的兼容性,制定了最低要求
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Load Characterization in Medium Voltage of an Electric Distribution Utility Related to Active Filters
The behavior of the actual load of an electric energy distribution utility by means of voltage and current measurements is analyzed in this paper. Steady and transient states are taken into account. The main attention is fixed in points where present shunt compensation is installed. Results of field measurements and the connection and disconnection of capacitor banks are shown. Studies for future compensation are detailed and the possible advantages of active filter incorporation are analyzed in order to replace or complement the existing compensation. The minimal requirements are established in order to consider the design of the active filters and their compatibility with the existing installations
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信