{"title":"用于感应无线电力传输的负载无关级EF逆变器","authors":"S. Aldhaher, P. Mitcheson, D. Yates","doi":"10.1109/WPT.2016.7498864","DOIUrl":null,"url":null,"abstract":"This paper will present the modelling, analysis and design of a load-independent Class EF inverter. This inverter is able to maintain zero-voltage switching (ZVS) operation and produce a constant output current for any load value without the need for tuning or replacement of components. The load-independent feature of this inverter is beneficial when used as the primary coil driver in multi-megahertz high power inductive wireless power transfer (WPT) applications where the distance between the coils and the load are variable. The work here begins with the traditional load-dependent Class EF topology for inversion and then specifies the criteria that are required to be met in order achieve load-independence. The design and development of a 240W load-independent Class EF inverter to drive the primary coil of a 6.78MHz WPT system will be discussed and experimental results will be presented to show the load-independence feature when the distance between the coils of the WPT system changes.","PeriodicalId":113182,"journal":{"name":"2016 IEEE Wireless Power Transfer Conference (WPTC)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"39","resultStr":"{\"title\":\"Load-independent Class EF inverters for inductive wireless power transfer\",\"authors\":\"S. Aldhaher, P. Mitcheson, D. Yates\",\"doi\":\"10.1109/WPT.2016.7498864\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper will present the modelling, analysis and design of a load-independent Class EF inverter. This inverter is able to maintain zero-voltage switching (ZVS) operation and produce a constant output current for any load value without the need for tuning or replacement of components. The load-independent feature of this inverter is beneficial when used as the primary coil driver in multi-megahertz high power inductive wireless power transfer (WPT) applications where the distance between the coils and the load are variable. The work here begins with the traditional load-dependent Class EF topology for inversion and then specifies the criteria that are required to be met in order achieve load-independence. The design and development of a 240W load-independent Class EF inverter to drive the primary coil of a 6.78MHz WPT system will be discussed and experimental results will be presented to show the load-independence feature when the distance between the coils of the WPT system changes.\",\"PeriodicalId\":113182,\"journal\":{\"name\":\"2016 IEEE Wireless Power Transfer Conference (WPTC)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"39\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Wireless Power Transfer Conference (WPTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WPT.2016.7498864\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Wireless Power Transfer Conference (WPTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WPT.2016.7498864","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 39

摘要

本文将介绍一种负载无关型变频逆变器的建模、分析和设计。该逆变器能够保持零电压开关(ZVS)操作,并产生恒定的输出电流,任何负载值,而无需调整或更换组件。在多兆赫高功率感应无线电力传输(WPT)应用中,当线圈与负载之间的距离是可变的时,该逆变器的负载无关特性是有益的。这里的工作从用于反演的传统负载相关类EF拓扑开始,然后指定为实现负载无关而需要满足的标准。本文讨论了用于驱动6.78MHz WPT系统初级线圈的240W无负载EF级逆变器的设计与开发,并给出了实验结果,以展示WPT系统线圈间距变化时的无负载特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Load-independent Class EF inverters for inductive wireless power transfer
This paper will present the modelling, analysis and design of a load-independent Class EF inverter. This inverter is able to maintain zero-voltage switching (ZVS) operation and produce a constant output current for any load value without the need for tuning or replacement of components. The load-independent feature of this inverter is beneficial when used as the primary coil driver in multi-megahertz high power inductive wireless power transfer (WPT) applications where the distance between the coils and the load are variable. The work here begins with the traditional load-dependent Class EF topology for inversion and then specifies the criteria that are required to be met in order achieve load-independence. The design and development of a 240W load-independent Class EF inverter to drive the primary coil of a 6.78MHz WPT system will be discussed and experimental results will be presented to show the load-independence feature when the distance between the coils of the WPT system changes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书