{"title":"超声图像中Savitzky-Golay滤波器降噪性能的研究","authors":"Simarjot Kaur Randhawa, R. K. Sunkaria","doi":"10.1109/ICSCCC.2018.8703303","DOIUrl":null,"url":null,"abstract":"Speckle noise is inherent nature of ultrasound images which makes interpretation of the images difficult and hence is undesirable. In this work, Savitzky-Golay filter is investigated for speckle reduction in ultrasound images. This filter is tested for different order and frame lengths. Optimal order and frame length is chosen heuristically by analyzing performance of the filter for a range of filter order and frame length. The method is tested on synthetic images as well as clinical ultrasound images and promising results are achieved.","PeriodicalId":148491,"journal":{"name":"2018 First International Conference on Secure Cyber Computing and Communication (ICSCCC)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Investigation of Performance of Savitzky-Golay Filter for Speckle Reduction in Ultrasound Images\",\"authors\":\"Simarjot Kaur Randhawa, R. K. Sunkaria\",\"doi\":\"10.1109/ICSCCC.2018.8703303\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Speckle noise is inherent nature of ultrasound images which makes interpretation of the images difficult and hence is undesirable. In this work, Savitzky-Golay filter is investigated for speckle reduction in ultrasound images. This filter is tested for different order and frame lengths. Optimal order and frame length is chosen heuristically by analyzing performance of the filter for a range of filter order and frame length. The method is tested on synthetic images as well as clinical ultrasound images and promising results are achieved.\",\"PeriodicalId\":148491,\"journal\":{\"name\":\"2018 First International Conference on Secure Cyber Computing and Communication (ICSCCC)\",\"volume\":\"105 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 First International Conference on Secure Cyber Computing and Communication (ICSCCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSCCC.2018.8703303\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 First International Conference on Secure Cyber Computing and Communication (ICSCCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSCCC.2018.8703303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of Performance of Savitzky-Golay Filter for Speckle Reduction in Ultrasound Images
Speckle noise is inherent nature of ultrasound images which makes interpretation of the images difficult and hence is undesirable. In this work, Savitzky-Golay filter is investigated for speckle reduction in ultrasound images. This filter is tested for different order and frame lengths. Optimal order and frame length is chosen heuristically by analyzing performance of the filter for a range of filter order and frame length. The method is tested on synthetic images as well as clinical ultrasound images and promising results are achieved.