滤过仪:一种测量人体静脉血血小板聚集的新装置。

G Hornstra, F ten Hoor
{"title":"滤过仪:一种测量人体静脉血血小板聚集的新装置。","authors":"G Hornstra,&nbsp;F ten Hoor","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A new device for the direct assessment of spontaneous platelet aggregation in human venous blood is described: the Filtragometer. The principle of the method is based on measurement of the pressure difference across a filter with pores of 20 mum diameter through which blood from a forearm vein is drawn. Platelet aggregates, obstructing the filter, cause a change in the pressure difference which is proportional to the degree of platelet aggregation. The measurement takes only a short time and a small amount (5-10 ml) of blood. Platelet aggregation as measured with the Filtragometer depends on the type of anticoagulant used. The Filtragometer response decreases on inhibition of platelet stickiness in vitro by prostaglandin E1 and in vivo by aspirin ingestion. Moreover it appeared to be higher in a group with a high thrombosis tendency than in a group less susceptible to fatal arterial thrombosis. The Filtragometer seems especially useful in monitoring the results of diet and/or drug therapy.</p>","PeriodicalId":23068,"journal":{"name":"Thrombosis et diathesis haemorrhagica","volume":"34 2","pages":"531-44"},"PeriodicalIF":0.0000,"publicationDate":"1975-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The filtragometer: a new device for measuring platelet aggregation in venous blood of man.\",\"authors\":\"G Hornstra,&nbsp;F ten Hoor\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A new device for the direct assessment of spontaneous platelet aggregation in human venous blood is described: the Filtragometer. The principle of the method is based on measurement of the pressure difference across a filter with pores of 20 mum diameter through which blood from a forearm vein is drawn. Platelet aggregates, obstructing the filter, cause a change in the pressure difference which is proportional to the degree of platelet aggregation. The measurement takes only a short time and a small amount (5-10 ml) of blood. Platelet aggregation as measured with the Filtragometer depends on the type of anticoagulant used. The Filtragometer response decreases on inhibition of platelet stickiness in vitro by prostaglandin E1 and in vivo by aspirin ingestion. Moreover it appeared to be higher in a group with a high thrombosis tendency than in a group less susceptible to fatal arterial thrombosis. The Filtragometer seems especially useful in monitoring the results of diet and/or drug therapy.</p>\",\"PeriodicalId\":23068,\"journal\":{\"name\":\"Thrombosis et diathesis haemorrhagica\",\"volume\":\"34 2\",\"pages\":\"531-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thrombosis et diathesis haemorrhagica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thrombosis et diathesis haemorrhagica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种直接测定人体静脉血中自发血小板聚集的新装置:滤光计。该方法的原理是基于测量一个直径为20微米的过滤器的压力差,从前臂静脉抽取血液。血小板聚集物阻塞过滤器,使压差发生变化,压差变化与血小板聚集程度成正比。测量只需要很短的时间和少量的血液(5-10毫升)。用滤过仪测量的血小板聚集取决于所用抗凝剂的类型。体外前列腺素E1抑制血小板黏性,体内阿司匹林抑制血小板黏性,滤过仪反应减弱。此外,血栓形成倾向高的人群似乎比不易发生致命动脉血栓形成的人群要高。滤过计在监测饮食和/或药物治疗的结果方面似乎特别有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The filtragometer: a new device for measuring platelet aggregation in venous blood of man.

A new device for the direct assessment of spontaneous platelet aggregation in human venous blood is described: the Filtragometer. The principle of the method is based on measurement of the pressure difference across a filter with pores of 20 mum diameter through which blood from a forearm vein is drawn. Platelet aggregates, obstructing the filter, cause a change in the pressure difference which is proportional to the degree of platelet aggregation. The measurement takes only a short time and a small amount (5-10 ml) of blood. Platelet aggregation as measured with the Filtragometer depends on the type of anticoagulant used. The Filtragometer response decreases on inhibition of platelet stickiness in vitro by prostaglandin E1 and in vivo by aspirin ingestion. Moreover it appeared to be higher in a group with a high thrombosis tendency than in a group less susceptible to fatal arterial thrombosis. The Filtragometer seems especially useful in monitoring the results of diet and/or drug therapy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信