热释光剂量计在计算机断层扫描仪上的辐射剂量测量

Dwenda Dexiana, M. Fathony
{"title":"热释光剂量计在计算机断层扫描仪上的辐射剂量测量","authors":"Dwenda Dexiana, M. Fathony","doi":"10.1109/ICICI-BME.2013.6698522","DOIUrl":null,"url":null,"abstract":"Computed Tomography scan is a method applied to examine the anatomy of a human body. A CT scan is also used as an alternative way to detect cancer. However due to the utilization of X-Rays, organs being examined are considered to be at risk of radiation effect. The purpose of this research is to measure absorbed radiation dose to meet the requirements of radiation protection on patients. A solid humanoid phantom was used to simulate the patient body. For the dose measurement, a lithium fluoride thermoluminescent dosemeters (TLD-100) were mounted within the head and neck area of the phantom. This research is also aimed to make the commonly used scanning protocol within a hospital to its full potential. This is done by comparing the radiation dose between different scanning protocols to find the smallest radiation exposure. It can be concluded that, the thicker the slice, the lower the exposed radiation dose will be.","PeriodicalId":316442,"journal":{"name":"2013 3rd International Conference on Instrumentation, Communications, Information Technology and Biomedical Engineering (ICICI-BME)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiation dose measurement on computed tomography scanner using thermoluminescent dosemeter\",\"authors\":\"Dwenda Dexiana, M. Fathony\",\"doi\":\"10.1109/ICICI-BME.2013.6698522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Computed Tomography scan is a method applied to examine the anatomy of a human body. A CT scan is also used as an alternative way to detect cancer. However due to the utilization of X-Rays, organs being examined are considered to be at risk of radiation effect. The purpose of this research is to measure absorbed radiation dose to meet the requirements of radiation protection on patients. A solid humanoid phantom was used to simulate the patient body. For the dose measurement, a lithium fluoride thermoluminescent dosemeters (TLD-100) were mounted within the head and neck area of the phantom. This research is also aimed to make the commonly used scanning protocol within a hospital to its full potential. This is done by comparing the radiation dose between different scanning protocols to find the smallest radiation exposure. It can be concluded that, the thicker the slice, the lower the exposed radiation dose will be.\",\"PeriodicalId\":316442,\"journal\":{\"name\":\"2013 3rd International Conference on Instrumentation, Communications, Information Technology and Biomedical Engineering (ICICI-BME)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 3rd International Conference on Instrumentation, Communications, Information Technology and Biomedical Engineering (ICICI-BME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICI-BME.2013.6698522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 3rd International Conference on Instrumentation, Communications, Information Technology and Biomedical Engineering (ICICI-BME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICI-BME.2013.6698522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

计算机断层扫描是一种用于检查人体解剖结构的方法。CT扫描也被用作检测癌症的另一种方法。然而,由于x射线的使用,被检查的器官被认为有受到辐射影响的危险。本研究的目的是测量吸收的辐射剂量,以满足患者对辐射防护的要求。采用实体人形假体模拟患者身体。为了测量剂量,将氟化锂热释光剂量计(TLD-100)安装在假体的头部和颈部区域。本研究还旨在使医院内常用的扫描协议充分发挥其潜力。这是通过比较不同扫描方案之间的辐射剂量来找到最小的辐射暴露来完成的。可见,切片越厚,照射剂量越低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiation dose measurement on computed tomography scanner using thermoluminescent dosemeter
Computed Tomography scan is a method applied to examine the anatomy of a human body. A CT scan is also used as an alternative way to detect cancer. However due to the utilization of X-Rays, organs being examined are considered to be at risk of radiation effect. The purpose of this research is to measure absorbed radiation dose to meet the requirements of radiation protection on patients. A solid humanoid phantom was used to simulate the patient body. For the dose measurement, a lithium fluoride thermoluminescent dosemeters (TLD-100) were mounted within the head and neck area of the phantom. This research is also aimed to make the commonly used scanning protocol within a hospital to its full potential. This is done by comparing the radiation dose between different scanning protocols to find the smallest radiation exposure. It can be concluded that, the thicker the slice, the lower the exposed radiation dose will be.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书