K. Muraoka, Y. Kawamura, Y. Ohtsubo, S. Sugawara, T. Tamamushi, J. Nishizawa
{"title":"高速硅晶闸管的特点及其应用作为60kHz、100kW和效率90%以上的逆变器","authors":"K. Muraoka, Y. Kawamura, Y. Ohtsubo, S. Sugawara, T. Tamamushi, J. Nishizawa","doi":"10.1109/PESC.1986.7415551","DOIUrl":null,"url":null,"abstract":"Very low-loss, very high speed and snubber-circuitless performance of the newly fabricated high power 1200V–300A class of the static induction (SI) thyristor is introduced and it is applied to the 60kHz–100kW high efficiency (90%) inverter for induction heating.","PeriodicalId":164857,"journal":{"name":"1986 17th Annual IEEE Power Electronics Specialists Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1986-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Characteristics of the high speed SI thyristor and its application as the 60kHz, 100kW and the efficiency of more than 90% inverter\",\"authors\":\"K. Muraoka, Y. Kawamura, Y. Ohtsubo, S. Sugawara, T. Tamamushi, J. Nishizawa\",\"doi\":\"10.1109/PESC.1986.7415551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Very low-loss, very high speed and snubber-circuitless performance of the newly fabricated high power 1200V–300A class of the static induction (SI) thyristor is introduced and it is applied to the 60kHz–100kW high efficiency (90%) inverter for induction heating.\",\"PeriodicalId\":164857,\"journal\":{\"name\":\"1986 17th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1986 17th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1986.7415551\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1986 17th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1986.7415551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Characteristics of the high speed SI thyristor and its application as the 60kHz, 100kW and the efficiency of more than 90% inverter
Very low-loss, very high speed and snubber-circuitless performance of the newly fabricated high power 1200V–300A class of the static induction (SI) thyristor is introduced and it is applied to the 60kHz–100kW high efficiency (90%) inverter for induction heating.