基于阻塞滤波装置的5次谐波电压含量孤岛检测方法

Chengcheng Xu, Huanhuan Fang, Yanping Zhu, Fangrui Chen, Daifu Fan
{"title":"基于阻塞滤波装置的5次谐波电压含量孤岛检测方法","authors":"Chengcheng Xu, Huanhuan Fang, Yanping Zhu, Fangrui Chen, Daifu Fan","doi":"10.1109/ICPEA56363.2022.10052440","DOIUrl":null,"url":null,"abstract":"Aiming at the problems of large blind area and low sensitivity of traditional passive islanding detection method for electric quantity change in harmonic domain, a new islanding detection method using 5-th harmonic voltage content with blocking filter device is proposed. The principle of the micro grid islanding detection scheme based on the 5-th harmonic voltage content is to judge whether the islanding effect occurs by detecting and comparing the changes of 5-th harmonic voltage content at the common coupling point before and after the blocking filter device. This paper introduces the process of the islanding detection scheme using the blocking filter device and the 5-th harmonic voltage content. Through theoretical analysis and MATLAB simulation, the correctness, economy, rapidity and reliability of the proposed method are verified.","PeriodicalId":447871,"journal":{"name":"2022 5th International Conference on Power and Energy Applications (ICPEA)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Islanding Detection Method Using 5-th Harmonic Voltage Content with Blocking Filter Device\",\"authors\":\"Chengcheng Xu, Huanhuan Fang, Yanping Zhu, Fangrui Chen, Daifu Fan\",\"doi\":\"10.1109/ICPEA56363.2022.10052440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aiming at the problems of large blind area and low sensitivity of traditional passive islanding detection method for electric quantity change in harmonic domain, a new islanding detection method using 5-th harmonic voltage content with blocking filter device is proposed. The principle of the micro grid islanding detection scheme based on the 5-th harmonic voltage content is to judge whether the islanding effect occurs by detecting and comparing the changes of 5-th harmonic voltage content at the common coupling point before and after the blocking filter device. This paper introduces the process of the islanding detection scheme using the blocking filter device and the 5-th harmonic voltage content. Through theoretical analysis and MATLAB simulation, the correctness, economy, rapidity and reliability of the proposed method are verified.\",\"PeriodicalId\":447871,\"journal\":{\"name\":\"2022 5th International Conference on Power and Energy Applications (ICPEA)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 5th International Conference on Power and Energy Applications (ICPEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEA56363.2022.10052440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 5th International Conference on Power and Energy Applications (ICPEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEA56363.2022.10052440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

针对传统谐波域电量变化无源孤岛检测方法存在盲区大、灵敏度低的问题,提出了一种基于5次谐波电压含量加阻塞滤波装置的孤岛检测方法。基于5次谐波电压含量的微电网孤岛检测方案的原理是,通过检测和比较阻断滤波装置前后共耦合点5次谐波电压含量的变化,判断是否发生孤岛效应。本文介绍了采用阻塞滤波装置和5次谐波电压含量的孤岛检测方案的过程。通过理论分析和MATLAB仿真,验证了该方法的正确性、经济性、快速性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Novel Islanding Detection Method Using 5-th Harmonic Voltage Content with Blocking Filter Device
Aiming at the problems of large blind area and low sensitivity of traditional passive islanding detection method for electric quantity change in harmonic domain, a new islanding detection method using 5-th harmonic voltage content with blocking filter device is proposed. The principle of the micro grid islanding detection scheme based on the 5-th harmonic voltage content is to judge whether the islanding effect occurs by detecting and comparing the changes of 5-th harmonic voltage content at the common coupling point before and after the blocking filter device. This paper introduces the process of the islanding detection scheme using the blocking filter device and the 5-th harmonic voltage content. Through theoretical analysis and MATLAB simulation, the correctness, economy, rapidity and reliability of the proposed method are verified.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信