用于细胞活力监测的浮栅电容传感器阵列

T. Datta, E. Naviasky, P. Abshire
{"title":"用于细胞活力监测的浮栅电容传感器阵列","authors":"T. Datta, E. Naviasky, P. Abshire","doi":"10.1109/BioCAS.2013.6679641","DOIUrl":null,"url":null,"abstract":"This paper describes a new design for a capacitance sensor array to monitor cell viability that uses floating gate compensation techniques to mitigate device mismatch. The measurement is carried out using sensor evaluation modules that employ a charge based capacitance measurement technique to quantify differential capacitance at the sensor pixel elements. Previous results from compensated structures and new data collected from in-vitro cell culture on the surface of an uncompensated array were used to inform the design of a new array. We examine array level architectural tradeoffs and sensing electrode configurations in order to design a high density sensor array with minimal sources of variability.","PeriodicalId":344317,"journal":{"name":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Floating-gate capacitance sensor array for cell viability monitoring\",\"authors\":\"T. Datta, E. Naviasky, P. Abshire\",\"doi\":\"10.1109/BioCAS.2013.6679641\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new design for a capacitance sensor array to monitor cell viability that uses floating gate compensation techniques to mitigate device mismatch. The measurement is carried out using sensor evaluation modules that employ a charge based capacitance measurement technique to quantify differential capacitance at the sensor pixel elements. Previous results from compensated structures and new data collected from in-vitro cell culture on the surface of an uncompensated array were used to inform the design of a new array. We examine array level architectural tradeoffs and sensing electrode configurations in order to design a high density sensor array with minimal sources of variability.\",\"PeriodicalId\":344317,\"journal\":{\"name\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BioCAS.2013.6679641\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2013.6679641","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文描述了一种电容传感器阵列的新设计,用于监测细胞活力,该阵列使用浮栅补偿技术来减轻器件失配。测量使用传感器评估模块进行,该模块采用基于电荷的电容测量技术来量化传感器像素元素处的差分电容。先前的补偿结构的结果和从非补偿阵列表面的体外细胞培养中收集的新数据被用来为新阵列的设计提供信息。我们研究阵列级架构权衡和传感电极配置,以便设计具有最小可变性源的高密度传感器阵列。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Floating-gate capacitance sensor array for cell viability monitoring
This paper describes a new design for a capacitance sensor array to monitor cell viability that uses floating gate compensation techniques to mitigate device mismatch. The measurement is carried out using sensor evaluation modules that employ a charge based capacitance measurement technique to quantify differential capacitance at the sensor pixel elements. Previous results from compensated structures and new data collected from in-vitro cell culture on the surface of an uncompensated array were used to inform the design of a new array. We examine array level architectural tradeoffs and sensing electrode configurations in order to design a high density sensor array with minimal sources of variability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信