C. Pawley, J. Scoville, R. Hong, T. Stevenson, G. Rossi, J. Edwards, A. von Halle
{"title":"DIII-D中性束流电力系统10秒运行分析","authors":"C. Pawley, J. Scoville, R. Hong, T. Stevenson, G. Rossi, J. Edwards, A. von Halle","doi":"10.1109/FUSION.2009.5226396","DOIUrl":null,"url":null,"abstract":"The neutral beam injector systems on the DIII-D tokamak are currently limited to 3 seconds of total beam on time with the existing beam line components. To achieve high performance discharges with a high fraction of non-inductive neutral beam current drive for pulse lengths longer than the resistive time, long pulse upgrades are planned for both the neutral beam line and the power supplies that drive it. The beam on time will be extended to 10 seconds to provide full drive throughout the tokamak shot.","PeriodicalId":236460,"journal":{"name":"2009 23rd IEEE/NPSS Symposium on Fusion Engineering","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of DIII-D neutral beam power systems for 10 second operation\",\"authors\":\"C. Pawley, J. Scoville, R. Hong, T. Stevenson, G. Rossi, J. Edwards, A. von Halle\",\"doi\":\"10.1109/FUSION.2009.5226396\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The neutral beam injector systems on the DIII-D tokamak are currently limited to 3 seconds of total beam on time with the existing beam line components. To achieve high performance discharges with a high fraction of non-inductive neutral beam current drive for pulse lengths longer than the resistive time, long pulse upgrades are planned for both the neutral beam line and the power supplies that drive it. The beam on time will be extended to 10 seconds to provide full drive throughout the tokamak shot.\",\"PeriodicalId\":236460,\"journal\":{\"name\":\"2009 23rd IEEE/NPSS Symposium on Fusion Engineering\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 23rd IEEE/NPSS Symposium on Fusion Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.2009.5226396\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 23rd IEEE/NPSS Symposium on Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.2009.5226396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of DIII-D neutral beam power systems for 10 second operation
The neutral beam injector systems on the DIII-D tokamak are currently limited to 3 seconds of total beam on time with the existing beam line components. To achieve high performance discharges with a high fraction of non-inductive neutral beam current drive for pulse lengths longer than the resistive time, long pulse upgrades are planned for both the neutral beam line and the power supplies that drive it. The beam on time will be extended to 10 seconds to provide full drive throughout the tokamak shot.