基于pv系统的斋浦尔和德拉敦1mw太阳能电站对比分析

Tanuj Rawat, Jyotsna Singh, Sachin Sharma
{"title":"基于pv系统的斋浦尔和德拉敦1mw太阳能电站对比分析","authors":"Tanuj Rawat, Jyotsna Singh, Sachin Sharma","doi":"10.1109/PIECON56912.2023.10085836","DOIUrl":null,"url":null,"abstract":"India is endowed with vast solar energy potential. Different areas of India receives different annual average solar radiations. Apart from photovoltaic (PV) module type and it’s orientation the efficiency of a solar plant is significantly effected by the geographical location. Therefore, in this paper performance of 1 MW grid connected roof top solar plant is assessed when it is located at two different locations of India. The two places are Jaipur in Rajasthan and Dehradun in Uttarakhand respectively. The simulation analysis is carried out using PVsyst software. A comparative analysis is presented in terms of energy injected by PV system into grid and different losses that are incurred in the 1 MW project for these two different locations.","PeriodicalId":182428,"journal":{"name":"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PVsyst Based Comparative Analysis of 1 MW Solar Plant in Jaipur and Dehradun\",\"authors\":\"Tanuj Rawat, Jyotsna Singh, Sachin Sharma\",\"doi\":\"10.1109/PIECON56912.2023.10085836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"India is endowed with vast solar energy potential. Different areas of India receives different annual average solar radiations. Apart from photovoltaic (PV) module type and it’s orientation the efficiency of a solar plant is significantly effected by the geographical location. Therefore, in this paper performance of 1 MW grid connected roof top solar plant is assessed when it is located at two different locations of India. The two places are Jaipur in Rajasthan and Dehradun in Uttarakhand respectively. The simulation analysis is carried out using PVsyst software. A comparative analysis is presented in terms of energy injected by PV system into grid and different losses that are incurred in the 1 MW project for these two different locations.\",\"PeriodicalId\":182428,\"journal\":{\"name\":\"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIECON56912.2023.10085836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIECON56912.2023.10085836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

印度拥有巨大的太阳能潜力。印度不同地区的年平均太阳辐射不同。除了光伏(PV)组件的类型和朝向外,太阳能发电厂的效率还受到地理位置的显著影响。因此,本文对位于印度两个不同地点的1mw并网屋顶太阳能电站的性能进行了评估。这两个地方分别是拉贾斯坦邦的斋浦尔和北阿坎德邦的德拉敦。利用PVsyst软件进行仿真分析。对比分析了两种不同地点的光伏发电系统向电网注入的能量和1mw项目产生的不同损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PVsyst Based Comparative Analysis of 1 MW Solar Plant in Jaipur and Dehradun
India is endowed with vast solar energy potential. Different areas of India receives different annual average solar radiations. Apart from photovoltaic (PV) module type and it’s orientation the efficiency of a solar plant is significantly effected by the geographical location. Therefore, in this paper performance of 1 MW grid connected roof top solar plant is assessed when it is located at two different locations of India. The two places are Jaipur in Rajasthan and Dehradun in Uttarakhand respectively. The simulation analysis is carried out using PVsyst software. A comparative analysis is presented in terms of energy injected by PV system into grid and different losses that are incurred in the 1 MW project for these two different locations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信