在一列中耗散的能量,与钢丝网和自缩混凝土成一个循环负荷

Hence Michael Wuaten
{"title":"在一列中耗散的能量,与钢丝网和自缩混凝土成一个循环负荷","authors":"Hence Michael Wuaten","doi":"10.35139/cantilever.v11i1.136","DOIUrl":null,"url":null,"abstract":"In structures located in earthquake-prone parts, energy dissipation capacity is one of the criteria that must be achieved by the structure. For old structures or built long before earthquake regulations were introduced, it becomes very vulnerable to earthquakes, so it necessitates to be anticipated to prevent collapse, and one method that can be done is by jacketing. In this subject field, testing was conducted using a cyclic load on a reinforced concrete square column measuring 300 mm x 300 mm, which jacketing using wire mesh and self-compacting concrete. From the test results, it was found that in specimens jacketed with M6 wire mesh and self-compacting concrete experienced an increase in accumulative energy dissipation by 23.32% with a relatively minor loss of strength.","PeriodicalId":338977,"journal":{"name":"Cantilever: Jurnal Penelitian dan Kajian Bidang Teknik Sipil","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Disipasi Energi Pada Kolom Dijacketing Dengan Wire Mesh dan Self Compacting Concrete Akibat Beban Siklik\",\"authors\":\"Hence Michael Wuaten\",\"doi\":\"10.35139/cantilever.v11i1.136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In structures located in earthquake-prone parts, energy dissipation capacity is one of the criteria that must be achieved by the structure. For old structures or built long before earthquake regulations were introduced, it becomes very vulnerable to earthquakes, so it necessitates to be anticipated to prevent collapse, and one method that can be done is by jacketing. In this subject field, testing was conducted using a cyclic load on a reinforced concrete square column measuring 300 mm x 300 mm, which jacketing using wire mesh and self-compacting concrete. From the test results, it was found that in specimens jacketed with M6 wire mesh and self-compacting concrete experienced an increase in accumulative energy dissipation by 23.32% with a relatively minor loss of strength.\",\"PeriodicalId\":338977,\"journal\":{\"name\":\"Cantilever: Jurnal Penelitian dan Kajian Bidang Teknik Sipil\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cantilever: Jurnal Penelitian dan Kajian Bidang Teknik Sipil\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35139/cantilever.v11i1.136\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cantilever: Jurnal Penelitian dan Kajian Bidang Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35139/cantilever.v11i1.136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在位于地震易发部位的结构中,消能能力是结构必须达到的指标之一。对于老建筑或者早在地震法规出台之前就建成的建筑,它们在地震前就变得非常脆弱,因此有必要对其进行预估,以防止其倒塌,而一种可以做到的方法是采用护套。在本课题领域中,试验采用循环荷载对尺寸为300 mm x 300 mm的钢筋混凝土方形柱进行了测试,该柱的护套采用钢丝网和自密实混凝土。试验结果表明,采用M6钢丝网和自密实混凝土护套的试件,其累计耗能增加23.32%,强度损失较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Disipasi Energi Pada Kolom Dijacketing Dengan Wire Mesh dan Self Compacting Concrete Akibat Beban Siklik
In structures located in earthquake-prone parts, energy dissipation capacity is one of the criteria that must be achieved by the structure. For old structures or built long before earthquake regulations were introduced, it becomes very vulnerable to earthquakes, so it necessitates to be anticipated to prevent collapse, and one method that can be done is by jacketing. In this subject field, testing was conducted using a cyclic load on a reinforced concrete square column measuring 300 mm x 300 mm, which jacketing using wire mesh and self-compacting concrete. From the test results, it was found that in specimens jacketed with M6 wire mesh and self-compacting concrete experienced an increase in accumulative energy dissipation by 23.32% with a relatively minor loss of strength.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信