小信号模型的灵敏度研究和校准

Joseph Leung, T. George
{"title":"小信号模型的灵敏度研究和校准","authors":"Joseph Leung, T. George","doi":"10.1109/APPEEC.2015.7381042","DOIUrl":null,"url":null,"abstract":"Inter-connectors are strategically important elements in the power system for their role in bulk power transfer between different areas. The dynamic performance of the interconnector is relatively less certain due to modelling complexity and difficulty in testing, despite its importance to power system security. This paper firstly presents the calibration result of the small signal power system dynamic models of the Australian National Electricity Market (NEM), using the field test measurements of SVC Power Oscillation Dampers in Queensland. Based on the calibrated models, the sensitivities of a number of parameters to system damping are evaluated. The results show that apart from the generator PSS design, the inter-area mode damping is also significantly influenced by the modelling of loads, generator (inertia in particular) and governor.","PeriodicalId":439089,"journal":{"name":"2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Sensitivity studies and calibration of small signal models\",\"authors\":\"Joseph Leung, T. George\",\"doi\":\"10.1109/APPEEC.2015.7381042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inter-connectors are strategically important elements in the power system for their role in bulk power transfer between different areas. The dynamic performance of the interconnector is relatively less certain due to modelling complexity and difficulty in testing, despite its importance to power system security. This paper firstly presents the calibration result of the small signal power system dynamic models of the Australian National Electricity Market (NEM), using the field test measurements of SVC Power Oscillation Dampers in Queensland. Based on the calibrated models, the sensitivities of a number of parameters to system damping are evaluated. The results show that apart from the generator PSS design, the inter-area mode damping is also significantly influenced by the modelling of loads, generator (inertia in particular) and governor.\",\"PeriodicalId\":439089,\"journal\":{\"name\":\"2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC.2015.7381042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2015.7381042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

互连器在电力系统中具有重要的战略意义,它在不同区域之间的大量电力传输中起着重要的作用。尽管互连器对电力系统安全至关重要,但由于建模复杂和测试困难,其动态性能相对不太确定。本文首先介绍了澳大利亚国家电力市场(NEM)小信号电力系统动态模型的标定结果,并利用昆士兰SVC功率振荡阻尼器的现场测试测量结果进行了标定。在标定模型的基础上,评估了多个参数对系统阻尼的敏感性。结果表明,除发电机PSS设计外,区域间模态阻尼还受到负载建模、发电机(特别是惯性)和调速器的显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sensitivity studies and calibration of small signal models
Inter-connectors are strategically important elements in the power system for their role in bulk power transfer between different areas. The dynamic performance of the interconnector is relatively less certain due to modelling complexity and difficulty in testing, despite its importance to power system security. This paper firstly presents the calibration result of the small signal power system dynamic models of the Australian National Electricity Market (NEM), using the field test measurements of SVC Power Oscillation Dampers in Queensland. Based on the calibrated models, the sensitivities of a number of parameters to system damping are evaluated. The results show that apart from the generator PSS design, the inter-area mode damping is also significantly influenced by the modelling of loads, generator (inertia in particular) and governor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信