Yang Xu, Tingting Ren, Tao Zhang, Wei Gong, Han Luo
{"title":"治疗用氙气光源设备计量性能评价的实验研究","authors":"Yang Xu, Tingting Ren, Tao Zhang, Wei Gong, Han Luo","doi":"10.1117/12.2673575","DOIUrl":null,"url":null,"abstract":"This article studies the key technical parameters such as “short wavelength boundary,” “energy density,” “energy output uniformity,” and “pulse duration” of xenon light source equipment for therapeutic use, determines the measurement standard, and presents an applicable metrological performance evaluation method for the equipment. The evaluation procedure presented in this article has been performed on several typical types of xenon light source equipment for therapeutic use widely used in China, and the experimental results show that the evaluation method presented in this article is scientific and effective, and can be adopted for the periodic calibration of the equipment, in order to establish the metrological traceability system of the equipment.","PeriodicalId":231020,"journal":{"name":"Biophysical Society of Guang Dong Province Academic Forum - Precise Photons and Life Health","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental research on metrological performance evaluation of xenon light source equipment for therapeutic use\",\"authors\":\"Yang Xu, Tingting Ren, Tao Zhang, Wei Gong, Han Luo\",\"doi\":\"10.1117/12.2673575\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article studies the key technical parameters such as “short wavelength boundary,” “energy density,” “energy output uniformity,” and “pulse duration” of xenon light source equipment for therapeutic use, determines the measurement standard, and presents an applicable metrological performance evaluation method for the equipment. The evaluation procedure presented in this article has been performed on several typical types of xenon light source equipment for therapeutic use widely used in China, and the experimental results show that the evaluation method presented in this article is scientific and effective, and can be adopted for the periodic calibration of the equipment, in order to establish the metrological traceability system of the equipment.\",\"PeriodicalId\":231020,\"journal\":{\"name\":\"Biophysical Society of Guang Dong Province Academic Forum - Precise Photons and Life Health\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biophysical Society of Guang Dong Province Academic Forum - Precise Photons and Life Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2673575\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophysical Society of Guang Dong Province Academic Forum - Precise Photons and Life Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2673575","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental research on metrological performance evaluation of xenon light source equipment for therapeutic use
This article studies the key technical parameters such as “short wavelength boundary,” “energy density,” “energy output uniformity,” and “pulse duration” of xenon light source equipment for therapeutic use, determines the measurement standard, and presents an applicable metrological performance evaluation method for the equipment. The evaluation procedure presented in this article has been performed on several typical types of xenon light source equipment for therapeutic use widely used in China, and the experimental results show that the evaluation method presented in this article is scientific and effective, and can be adopted for the periodic calibration of the equipment, in order to establish the metrological traceability system of the equipment.