检测局部放电的新型脉冲电压发生器的评价

T. Ueno, Hirotaka Nakaya, M. Kozako, M. Hikita, T. Ikegami, T. Sakurai, H. Ogawa, T. Kisakibaru, S. Yamada, T. Yoshimitsu, T. Hirose, S. Hiroshima
{"title":"检测局部放电的新型脉冲电压发生器的评价","authors":"T. Ueno, Hirotaka Nakaya, M. Kozako, M. Hikita, T. Ikegami, T. Sakurai, H. Ogawa, T. Kisakibaru, S. Yamada, T. Yoshimitsu, T. Hirose, S. Hiroshima","doi":"10.1109/CEIDP.2013.6748143","DOIUrl":null,"url":null,"abstract":"The Inverter surge is a high-voltage phenomenon that is generated by the overlap returning wave by impedance mismatching to an inverter and load like cables and motors. The inverter has been available by advancement of control system of electrical instrument, such as the industrial motor. The increase of current changing rate with the advance of power semiconductor causes the surge voltage to rise, increasing the number of failure events. The evaluation technology by partial discharge (PD) measurement is important because the mechanism leading to breakdown by the inverter surge is a cause of PD. In this study, a repetitive impulse voltage generator has been developed which is used in detecting PD in the inverter surge. We report the result that repetitive impulse voltage was applied to confirm the insulation dignity of inverter-fed motor insulation using the repetitive impulse voltage generator.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"447 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Evaluation of novel impulse voltage generator for detecting partial discharge\",\"authors\":\"T. Ueno, Hirotaka Nakaya, M. Kozako, M. Hikita, T. Ikegami, T. Sakurai, H. Ogawa, T. Kisakibaru, S. Yamada, T. Yoshimitsu, T. Hirose, S. Hiroshima\",\"doi\":\"10.1109/CEIDP.2013.6748143\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Inverter surge is a high-voltage phenomenon that is generated by the overlap returning wave by impedance mismatching to an inverter and load like cables and motors. The inverter has been available by advancement of control system of electrical instrument, such as the industrial motor. The increase of current changing rate with the advance of power semiconductor causes the surge voltage to rise, increasing the number of failure events. The evaluation technology by partial discharge (PD) measurement is important because the mechanism leading to breakdown by the inverter surge is a cause of PD. In this study, a repetitive impulse voltage generator has been developed which is used in detecting PD in the inverter surge. We report the result that repetitive impulse voltage was applied to confirm the insulation dignity of inverter-fed motor insulation using the repetitive impulse voltage generator.\",\"PeriodicalId\":393969,\"journal\":{\"name\":\"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"447 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2013.6748143\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6748143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

逆变器浪涌是一种高压现象,它是由逆变器和负载(如电缆和电机)的阻抗不匹配引起的重叠返回波产生的。随着工业电机等电气仪表控制系统的发展,变频器已成为可能。随着功率半导体技术的发展,电流变化率的增加导致浪涌电压的升高,从而增加了故障事件的数量。局部放电(PD)测量评估技术具有重要意义,因为逆变器浪涌导致击穿的机理是局部放电产生的原因之一。本研究开发了一种重复脉冲电压发生器,用于检测逆变器浪涌中的局部放电。本文报道了用重复冲击电压发生器确定逆变电机绝缘质量的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of novel impulse voltage generator for detecting partial discharge
The Inverter surge is a high-voltage phenomenon that is generated by the overlap returning wave by impedance mismatching to an inverter and load like cables and motors. The inverter has been available by advancement of control system of electrical instrument, such as the industrial motor. The increase of current changing rate with the advance of power semiconductor causes the surge voltage to rise, increasing the number of failure events. The evaluation technology by partial discharge (PD) measurement is important because the mechanism leading to breakdown by the inverter surge is a cause of PD. In this study, a repetitive impulse voltage generator has been developed which is used in detecting PD in the inverter surge. We report the result that repetitive impulse voltage was applied to confirm the insulation dignity of inverter-fed motor insulation using the repetitive impulse voltage generator.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信