{"title":"并网转子系dfig型WECS定子侧控制的实验实现","authors":"M. W. K. Mbukani, N. Gule","doi":"10.1109/SPEEDAM.2018.8445362","DOIUrl":null,"url":null,"abstract":"In the rotor-tied configuration of the doubly-fed induction generator (DFIG), the rotor is connected to the grid whilst the stator of the DFIG is connected to the grid through a back-to-back converter. In this paper, the modelling and control algorithm of the stator-side converter of a custom-designed S.S-kW rotor-tied DFIG are presented. Furthermore, the performance of the proposed control algorithm is experimentally evaluated during synchronisation and in sub-synchronous operating conditions.","PeriodicalId":117883,"journal":{"name":"2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Experimental Implementation of The Stator-Side Control of a Grid-Connected Rotor-Tied DFIG-Based WECS\",\"authors\":\"M. W. K. Mbukani, N. Gule\",\"doi\":\"10.1109/SPEEDAM.2018.8445362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the rotor-tied configuration of the doubly-fed induction generator (DFIG), the rotor is connected to the grid whilst the stator of the DFIG is connected to the grid through a back-to-back converter. In this paper, the modelling and control algorithm of the stator-side converter of a custom-designed S.S-kW rotor-tied DFIG are presented. Furthermore, the performance of the proposed control algorithm is experimentally evaluated during synchronisation and in sub-synchronous operating conditions.\",\"PeriodicalId\":117883,\"journal\":{\"name\":\"2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEEDAM.2018.8445362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2018.8445362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental Implementation of The Stator-Side Control of a Grid-Connected Rotor-Tied DFIG-Based WECS
In the rotor-tied configuration of the doubly-fed induction generator (DFIG), the rotor is connected to the grid whilst the stator of the DFIG is connected to the grid through a back-to-back converter. In this paper, the modelling and control algorithm of the stator-side converter of a custom-designed S.S-kW rotor-tied DFIG are presented. Furthermore, the performance of the proposed control algorithm is experimentally evaluated during synchronisation and in sub-synchronous operating conditions.