K. Das, S. A. Begum, S. Dey, M. Quddus, A. Mohiuddin
{"title":"超声测量下腔静脉内径——一种检测急性失血的无创工具","authors":"K. Das, S. A. Begum, S. Dey, M. Quddus, A. Mohiuddin","doi":"10.3329/IMCJ.V5I2.10099","DOIUrl":null,"url":null,"abstract":"Detection and monitoring of blood loss in trauma patients can often be challenging. Change in the inferior vena cava diameter (IVCd) occurs due to alteration in circulating blood volume (CBV) and blood loss. Ultrasonographic measurement of IVCd provides a noninvasive real-time information of the CBV. The present study was designed to determine whether acute blood loss could be detected by sonographic measurement of the IVCd. A total of 50 volunteer blood donors aged 18 to 57 years were studied in the Department of Radiology and Imaging of Dhaka Medical College Hospital (DMCH) from July 2004 to June 2005. The inferior vena cava diameters, both during inspiration and expiration were measured by ultrasound examination immediately before and after donation of a single unit (450ml) of blood. During examination, the transducer was applied to the epigastrium parallel to the median line about 2 cm to the right of it for sagittal sections, and at a right angle to the median line about 3 cm below the xiphoid process for transverse sections. In sagittal sections, the inferior vena cava behind the liver were imaged during inspiration and expiration. The mean diameter of IVC during expiration before and after the blood donation was 17.5mm (±1.56mm) and 11.93mm (±1.48mm) respectively. Likewise, the mean diameter of IVC during inspiration before and after the blood donation was 12.96mm (±1.61mm) and 7.58mm (±1.29mm) respectively. The decrease in INV diameter following blood loss was significant (p< 0.01). Thus, the acute depletion of CBV could be detected by measuring the change of IVCd by sonography. Further study may be undertaken to determine the relationship of unit change of IVCd due to acute blood loss in case of trauma or other conditions. DOI: http://dx.doi.org/10.3329/imcj.v5i2.10099 IMCJ 2011; 5(2): 51-53","PeriodicalId":226732,"journal":{"name":"Ibrahim Medical College Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Sonographic Measurement Of Inferior Vena Cava Diameter A Noninvasive Tool To Detect Acute Blood Loss\",\"authors\":\"K. Das, S. A. Begum, S. Dey, M. Quddus, A. Mohiuddin\",\"doi\":\"10.3329/IMCJ.V5I2.10099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Detection and monitoring of blood loss in trauma patients can often be challenging. Change in the inferior vena cava diameter (IVCd) occurs due to alteration in circulating blood volume (CBV) and blood loss. Ultrasonographic measurement of IVCd provides a noninvasive real-time information of the CBV. The present study was designed to determine whether acute blood loss could be detected by sonographic measurement of the IVCd. A total of 50 volunteer blood donors aged 18 to 57 years were studied in the Department of Radiology and Imaging of Dhaka Medical College Hospital (DMCH) from July 2004 to June 2005. The inferior vena cava diameters, both during inspiration and expiration were measured by ultrasound examination immediately before and after donation of a single unit (450ml) of blood. During examination, the transducer was applied to the epigastrium parallel to the median line about 2 cm to the right of it for sagittal sections, and at a right angle to the median line about 3 cm below the xiphoid process for transverse sections. In sagittal sections, the inferior vena cava behind the liver were imaged during inspiration and expiration. The mean diameter of IVC during expiration before and after the blood donation was 17.5mm (±1.56mm) and 11.93mm (±1.48mm) respectively. Likewise, the mean diameter of IVC during inspiration before and after the blood donation was 12.96mm (±1.61mm) and 7.58mm (±1.29mm) respectively. The decrease in INV diameter following blood loss was significant (p< 0.01). Thus, the acute depletion of CBV could be detected by measuring the change of IVCd by sonography. Further study may be undertaken to determine the relationship of unit change of IVCd due to acute blood loss in case of trauma or other conditions. DOI: http://dx.doi.org/10.3329/imcj.v5i2.10099 IMCJ 2011; 5(2): 51-53\",\"PeriodicalId\":226732,\"journal\":{\"name\":\"Ibrahim Medical College Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ibrahim Medical College Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3329/IMCJ.V5I2.10099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ibrahim Medical College Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3329/IMCJ.V5I2.10099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

检测和监测创伤患者的失血往往具有挑战性。下腔静脉直径(IVCd)的改变是由于循环血容量(CBV)和失血的改变而发生的。超声测量IVCd提供了CBV的无创实时信息。本研究旨在确定超声测量IVCd是否可以检测急性失血。2004年7月至2005年6月,在达卡医学院医院(DMCH)放射学和影像科对50名年龄在18至57岁之间的志愿献血者进行了研究。在单单位(450ml)献血前后立即进行超声检查,测量吸气和呼气时下腔静脉直径。检查时,矢状面将换能器置于与上腹部右侧中线平行约2cm的上腹部,横切面将换能器置于剑突下方约3cm的上腹部与中线成直角。在矢状面上,吸气和呼气时显示肝后下腔静脉。献血前后下腔静脉平均直径分别为17.5mm(±1.56mm)和11.93mm(±1.48mm)。同样,献血前后吸气时下腔静脉平均直径分别为12.96mm(±1.61mm)和7.58mm(±1.29mm)。出血后静脉内径明显减小(p< 0.01)。因此,超声可以通过测量IVCd的变化来检测CBV的急性耗竭。外伤或其他情况下急性失血与IVCd单位变化的关系有待进一步研究。DOI: http://dx.doi.org/10.3329/imcj.v5i2.10099 IMCJ 2011;5(2):。51号~ 53号
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sonographic Measurement Of Inferior Vena Cava Diameter A Noninvasive Tool To Detect Acute Blood Loss
Detection and monitoring of blood loss in trauma patients can often be challenging. Change in the inferior vena cava diameter (IVCd) occurs due to alteration in circulating blood volume (CBV) and blood loss. Ultrasonographic measurement of IVCd provides a noninvasive real-time information of the CBV. The present study was designed to determine whether acute blood loss could be detected by sonographic measurement of the IVCd. A total of 50 volunteer blood donors aged 18 to 57 years were studied in the Department of Radiology and Imaging of Dhaka Medical College Hospital (DMCH) from July 2004 to June 2005. The inferior vena cava diameters, both during inspiration and expiration were measured by ultrasound examination immediately before and after donation of a single unit (450ml) of blood. During examination, the transducer was applied to the epigastrium parallel to the median line about 2 cm to the right of it for sagittal sections, and at a right angle to the median line about 3 cm below the xiphoid process for transverse sections. In sagittal sections, the inferior vena cava behind the liver were imaged during inspiration and expiration. The mean diameter of IVC during expiration before and after the blood donation was 17.5mm (±1.56mm) and 11.93mm (±1.48mm) respectively. Likewise, the mean diameter of IVC during inspiration before and after the blood donation was 12.96mm (±1.61mm) and 7.58mm (±1.29mm) respectively. The decrease in INV diameter following blood loss was significant (p< 0.01). Thus, the acute depletion of CBV could be detected by measuring the change of IVCd by sonography. Further study may be undertaken to determine the relationship of unit change of IVCd due to acute blood loss in case of trauma or other conditions. DOI: http://dx.doi.org/10.3329/imcj.v5i2.10099 IMCJ 2011; 5(2): 51-53
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信