{"title":"术中诱发电位监测系统的放大器输入保护电路","authors":"I. Krois, V. Isgum, M. Cifrek","doi":"10.1109/MELCON.2004.1346775","DOIUrl":null,"url":null,"abstract":"In this paper a short introduction into problem of intraoperative interference will be presented. Three most important types of interferences will be analyzed. Connection between their physical properties and scheme of protection circuit will be shown. At the example of realized protection circuit we will show what are additional problems in hardware realization.","PeriodicalId":164818,"journal":{"name":"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)","volume":"423 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The amplifier input protection circuit for a intraoperative evoked potential monitoring system\",\"authors\":\"I. Krois, V. Isgum, M. Cifrek\",\"doi\":\"10.1109/MELCON.2004.1346775\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a short introduction into problem of intraoperative interference will be presented. Three most important types of interferences will be analyzed. Connection between their physical properties and scheme of protection circuit will be shown. At the example of realized protection circuit we will show what are additional problems in hardware realization.\",\"PeriodicalId\":164818,\"journal\":{\"name\":\"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)\",\"volume\":\"423 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MELCON.2004.1346775\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.2004.1346775","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The amplifier input protection circuit for a intraoperative evoked potential monitoring system
In this paper a short introduction into problem of intraoperative interference will be presented. Three most important types of interferences will be analyzed. Connection between their physical properties and scheme of protection circuit will be shown. At the example of realized protection circuit we will show what are additional problems in hardware realization.