心率重建用电测生理参数系统

J.L. Kalju, K. Meigas, H. Hinrikus, J. Kaik
{"title":"心率重建用电测生理参数系统","authors":"J.L. Kalju, K. Meigas, H. Hinrikus, J. Kaik","doi":"10.1109/ICBEM.1998.666441","DOIUrl":null,"url":null,"abstract":"The system of different electrically measured physiological parameters have been investigated to develop a model for heart rate reconstruction for rate adaptive pacing. There were three different parameters under examination: QT interval, ventilation volume and physical activity. The simultaneous non-invasive measurements of ECG, transthoracic impedance and physical activity for a group of healthy persons during different predetermined exercise tests and normal daily activities have been carried out. A special multichannel recording instrument has been developed for noninvasive registration of signals. Linear combination of QT and activity parameters gives a relatively simple, but satisfactory bases for heart rate reconstruction for rate adaptive cardiac pacing purposes. The developed model was tested with the group of persons and relative mean squared error between calculated and natural heart rate for the group turned to be 8.4%.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"102 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"System of electrically measured physiological parameters for reconstruction of heart rate\",\"authors\":\"J.L. Kalju, K. Meigas, H. Hinrikus, J. Kaik\",\"doi\":\"10.1109/ICBEM.1998.666441\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The system of different electrically measured physiological parameters have been investigated to develop a model for heart rate reconstruction for rate adaptive pacing. There were three different parameters under examination: QT interval, ventilation volume and physical activity. The simultaneous non-invasive measurements of ECG, transthoracic impedance and physical activity for a group of healthy persons during different predetermined exercise tests and normal daily activities have been carried out. A special multichannel recording instrument has been developed for noninvasive registration of signals. Linear combination of QT and activity parameters gives a relatively simple, but satisfactory bases for heart rate reconstruction for rate adaptive cardiac pacing purposes. The developed model was tested with the group of persons and relative mean squared error between calculated and natural heart rate for the group turned to be 8.4%.\",\"PeriodicalId\":213764,\"journal\":{\"name\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"volume\":\"102 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBEM.1998.666441\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEM.1998.666441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了不同电测生理参数的系统,建立了心率自适应起搏的心率重建模型。检查三个不同的参数:QT间期、通气量和体力活动。对一组健康人进行不同的预定运动试验和正常的日常活动,同时进行心电图、经胸阻抗和身体活动的无创测量。研制了一种特殊的多通道记录仪器,用于信号的无创配准。QT和活动参数的线性组合提供了相对简单但令人满意的心率重建基础,用于心率适应性心脏起搏目的。建立的模型与人群进行了测试,计算心率与自然心率之间的相对均方误差为8.4%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
System of electrically measured physiological parameters for reconstruction of heart rate
The system of different electrically measured physiological parameters have been investigated to develop a model for heart rate reconstruction for rate adaptive pacing. There were three different parameters under examination: QT interval, ventilation volume and physical activity. The simultaneous non-invasive measurements of ECG, transthoracic impedance and physical activity for a group of healthy persons during different predetermined exercise tests and normal daily activities have been carried out. A special multichannel recording instrument has been developed for noninvasive registration of signals. Linear combination of QT and activity parameters gives a relatively simple, but satisfactory bases for heart rate reconstruction for rate adaptive cardiac pacing purposes. The developed model was tested with the group of persons and relative mean squared error between calculated and natural heart rate for the group turned to be 8.4%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信