{"title":"IEC 60079-14《电气装置设计、选择和安装》","authors":"B. Keane, G. Schwarz, P. Thurnherr","doi":"10.1109/PCICON.2014.6961902","DOIUrl":null,"url":null,"abstract":"In addition to more precise specifications, Edition 5 of IEC 60079-14, “Electrical installations design, selection and erection”, also contains some important innovations. This standard also applies to hazardous locations. · The documents required for the site, the equipment, the installation and the verification of the competence of employees · The initial inspection · Battery-powered equipment shall be certified for Gas Group IIC · Cables in hazardous areas shall be round and compact. The requirements also apply for cables for intrinsically safe circuits · Cable glands · New requirements for enclosures for more than one intrinsically safe circuit · Consideration of the dissipation power of terminal boxes.","PeriodicalId":264800,"journal":{"name":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"IEC 60079-14 “Electrical installations design, selection and erection”\",\"authors\":\"B. Keane, G. Schwarz, P. Thurnherr\",\"doi\":\"10.1109/PCICON.2014.6961902\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In addition to more precise specifications, Edition 5 of IEC 60079-14, “Electrical installations design, selection and erection”, also contains some important innovations. This standard also applies to hazardous locations. · The documents required for the site, the equipment, the installation and the verification of the competence of employees · The initial inspection · Battery-powered equipment shall be certified for Gas Group IIC · Cables in hazardous areas shall be round and compact. The requirements also apply for cables for intrinsically safe circuits · Cable glands · New requirements for enclosures for more than one intrinsically safe circuit · Consideration of the dissipation power of terminal boxes.\",\"PeriodicalId\":264800,\"journal\":{\"name\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCICON.2014.6961902\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCICON.2014.6961902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
IEC 60079-14 “Electrical installations design, selection and erection”
In addition to more precise specifications, Edition 5 of IEC 60079-14, “Electrical installations design, selection and erection”, also contains some important innovations. This standard also applies to hazardous locations. · The documents required for the site, the equipment, the installation and the verification of the competence of employees · The initial inspection · Battery-powered equipment shall be certified for Gas Group IIC · Cables in hazardous areas shall be round and compact. The requirements also apply for cables for intrinsically safe circuits · Cable glands · New requirements for enclosures for more than one intrinsically safe circuit · Consideration of the dissipation power of terminal boxes.