恒中切牙冠根角的测量

Pamela Zúñiga, Daniela Albers
{"title":"恒中切牙冠根角的测量","authors":"Pamela Zúñiga, Daniela Albers","doi":"10.4067/s0718-381x2023000100077","DOIUrl":null,"url":null,"abstract":"˚˚ ABSTRACT: The anatomical variations of teeth are directly related to the esthetics achieved in orthodontic treatment. These variations include the dental axes, such as the long crown axis and the long root axis. For this reason, these axes and the angle formed by their intersection, or crown-root angle, have been studied using several methodologies, mainly in central incisors. This study aimed to propose the visual- spatial processing as a method to determine the long crown axis and the long root axis, and thus measure the angle between these axes (crown-root angle) in the permanent upper and lower central incisors. The study had a quantitative, descriptive, observational and cross- sectional approach. The study sample consisted of 100 Cone-beam computed tomography (CBCT) images: 50 of permanent upper central incisors and 50 of permanent lower central incisors. The crown-root angle was measured considering the long crown axis and the long root axis. The mean crown root angle in the upper central incisors was 21.34 (cid:176) , with a standard deviation (SD) of 4.41…; for the lower central incisors, the mean value was 20.05… with a SD of 4.18…. This study suggests that the visual-spatial processing can be a valid method to determine the long crown axis and the long root axis, also with the advantage of not requiring specific instruments and anatomical reference points, which simplifies the tracing of axes and thus measurement of the crown-root angle.","PeriodicalId":177464,"journal":{"name":"International journal of odontostomatology","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Crown-Root Angle Measurement in Permanent Central Incisors\",\"authors\":\"Pamela Zúñiga, Daniela Albers\",\"doi\":\"10.4067/s0718-381x2023000100077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"˚˚ ABSTRACT: The anatomical variations of teeth are directly related to the esthetics achieved in orthodontic treatment. These variations include the dental axes, such as the long crown axis and the long root axis. For this reason, these axes and the angle formed by their intersection, or crown-root angle, have been studied using several methodologies, mainly in central incisors. This study aimed to propose the visual- spatial processing as a method to determine the long crown axis and the long root axis, and thus measure the angle between these axes (crown-root angle) in the permanent upper and lower central incisors. The study had a quantitative, descriptive, observational and cross- sectional approach. The study sample consisted of 100 Cone-beam computed tomography (CBCT) images: 50 of permanent upper central incisors and 50 of permanent lower central incisors. The crown-root angle was measured considering the long crown axis and the long root axis. The mean crown root angle in the upper central incisors was 21.34 (cid:176) , with a standard deviation (SD) of 4.41…; for the lower central incisors, the mean value was 20.05… with a SD of 4.18…. This study suggests that the visual-spatial processing can be a valid method to determine the long crown axis and the long root axis, also with the advantage of not requiring specific instruments and anatomical reference points, which simplifies the tracing of axes and thus measurement of the crown-root angle.\",\"PeriodicalId\":177464,\"journal\":{\"name\":\"International journal of odontostomatology\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of odontostomatology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4067/s0718-381x2023000100077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of odontostomatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4067/s0718-381x2023000100077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要:牙齿解剖形态的变化直接关系到正畸治疗的美观性。这些变化包括牙齿轴,如长冠轴和长根轴。由于这个原因,这些轴和它们相交形成的角度,或冠根角,已经用几种方法进行了研究,主要是在中门牙。本研究旨在提出一种视觉空间处理的方法,以确定长冠轴和长根轴,从而测量这两轴之间的夹角(冠根角)在永久上、下中切牙。该研究采用定量、描述性、观察性和横断面方法。研究样本包括100张锥形束ct (Cone-beam computed tomography, CBCT)图像,其中50张为恒上中切牙,50张为恒下中切牙。考虑长冠轴和长根轴,测量冠根角。上中切牙冠根角平均值为21.34 (cid:176),标准差(SD)为4.41…;下中切牙的平均值为20.05…,SD为4.18....本研究表明,视觉空间处理可以作为一种有效的方法来确定长冠轴和长根轴,并且不需要特定的仪器和解剖参考点,从而简化了轴的跟踪,从而简化了冠根角的测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Crown-Root Angle Measurement in Permanent Central Incisors
˚˚ ABSTRACT: The anatomical variations of teeth are directly related to the esthetics achieved in orthodontic treatment. These variations include the dental axes, such as the long crown axis and the long root axis. For this reason, these axes and the angle formed by their intersection, or crown-root angle, have been studied using several methodologies, mainly in central incisors. This study aimed to propose the visual- spatial processing as a method to determine the long crown axis and the long root axis, and thus measure the angle between these axes (crown-root angle) in the permanent upper and lower central incisors. The study had a quantitative, descriptive, observational and cross- sectional approach. The study sample consisted of 100 Cone-beam computed tomography (CBCT) images: 50 of permanent upper central incisors and 50 of permanent lower central incisors. The crown-root angle was measured considering the long crown axis and the long root axis. The mean crown root angle in the upper central incisors was 21.34 (cid:176) , with a standard deviation (SD) of 4.41…; for the lower central incisors, the mean value was 20.05… with a SD of 4.18…. This study suggests that the visual-spatial processing can be a valid method to determine the long crown axis and the long root axis, also with the advantage of not requiring specific instruments and anatomical reference points, which simplifies the tracing of axes and thus measurement of the crown-root angle.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信