在达沃医生医院对Elekta Synergy平台直线机进行10 MV光子束的PRIMO蒙特卡罗验证:在达沃医生医院对Elekta Synergy平台直线机进行10 MV光子束的PRIMO蒙特卡罗验证

V. Convicto, Jan Risty L. Marzon, Andelson L. Berondo, A. Bacala
{"title":"在达沃医生医院对Elekta Synergy平台直线机进行10 MV光子束的PRIMO蒙特卡罗验证:在达沃医生医院对Elekta Synergy平台直线机进行10 MV光子束的PRIMO蒙特卡罗验证","authors":"V. Convicto, Jan Risty L. Marzon, Andelson L. Berondo, A. Bacala","doi":"10.1145/3502060.3503619","DOIUrl":null,"url":null,"abstract":"Using PRIMO Monte Carlo (MC) software package, 10 MV photons from an Elekta MLCi linac are simulated. To validate the MC model, the simulated beam data are benchmarked against measured data from an Elekta Synergy Platform linac at Davao Doctors Hospital [DDH] in the southern Philippines. This requires fine-tuning of the electron beam parameters namely; electron beam's initial energy, full-with-half-maximum (FWHM) of the energy, focal spot size FWHM and beam divergence. The fine-tuning process of linac with megavoltage photon beams involves optimization of the electron beam's initial energy and this optimized value is then input to subsequent simulations to reproduce the lateral beam profiles. The lowest gamma index passing criteria of 1%/1mm is used as determinant in finding the matching values of all beam parameters. The percentage depth dose (PDD) and lateral profile dose distributions are calculated for treatment field sizes of 5 × 5 cm2 and 20 × 20 cm2 at source-to-surface distance of 100 cm in a homogeneous phantom. The optimized beam configurations are then simulated at higher statistics to verify the good agreement with measurements.","PeriodicalId":133132,"journal":{"name":"International Symposium on Biomedical Engineering and Computational Biology","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PRIMO Monte Carlo validation of Elekta Synergy Platform linac at Davao Doctors Hospital for a 10 MV photon beam: PRIMO Monte Carlo validation of Elekta Synergy Platform linac at Davao Doctors Hospital for a 10 MV photon beam\",\"authors\":\"V. Convicto, Jan Risty L. Marzon, Andelson L. Berondo, A. Bacala\",\"doi\":\"10.1145/3502060.3503619\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using PRIMO Monte Carlo (MC) software package, 10 MV photons from an Elekta MLCi linac are simulated. To validate the MC model, the simulated beam data are benchmarked against measured data from an Elekta Synergy Platform linac at Davao Doctors Hospital [DDH] in the southern Philippines. This requires fine-tuning of the electron beam parameters namely; electron beam's initial energy, full-with-half-maximum (FWHM) of the energy, focal spot size FWHM and beam divergence. The fine-tuning process of linac with megavoltage photon beams involves optimization of the electron beam's initial energy and this optimized value is then input to subsequent simulations to reproduce the lateral beam profiles. The lowest gamma index passing criteria of 1%/1mm is used as determinant in finding the matching values of all beam parameters. The percentage depth dose (PDD) and lateral profile dose distributions are calculated for treatment field sizes of 5 × 5 cm2 and 20 × 20 cm2 at source-to-surface distance of 100 cm in a homogeneous phantom. The optimized beam configurations are then simulated at higher statistics to verify the good agreement with measurements.\",\"PeriodicalId\":133132,\"journal\":{\"name\":\"International Symposium on Biomedical Engineering and Computational Biology\",\"volume\":\"106 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Biomedical Engineering and Computational Biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3502060.3503619\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Biomedical Engineering and Computational Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3502060.3503619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
PRIMO Monte Carlo validation of Elekta Synergy Platform linac at Davao Doctors Hospital for a 10 MV photon beam: PRIMO Monte Carlo validation of Elekta Synergy Platform linac at Davao Doctors Hospital for a 10 MV photon beam
Using PRIMO Monte Carlo (MC) software package, 10 MV photons from an Elekta MLCi linac are simulated. To validate the MC model, the simulated beam data are benchmarked against measured data from an Elekta Synergy Platform linac at Davao Doctors Hospital [DDH] in the southern Philippines. This requires fine-tuning of the electron beam parameters namely; electron beam's initial energy, full-with-half-maximum (FWHM) of the energy, focal spot size FWHM and beam divergence. The fine-tuning process of linac with megavoltage photon beams involves optimization of the electron beam's initial energy and this optimized value is then input to subsequent simulations to reproduce the lateral beam profiles. The lowest gamma index passing criteria of 1%/1mm is used as determinant in finding the matching values of all beam parameters. The percentage depth dose (PDD) and lateral profile dose distributions are calculated for treatment field sizes of 5 × 5 cm2 and 20 × 20 cm2 at source-to-surface distance of 100 cm in a homogeneous phantom. The optimized beam configurations are then simulated at higher statistics to verify the good agreement with measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信